Bluemke D A, Breiter S N
Department of Radiology, Johns Hopkins Hospital, Baltimore, MD 21287, USA.
Radiology. 2000 Sep;216(3):645-52. doi: 10.1148/radiology.216.3.r00se45645.
To measure the safety and effectiveness of conscious sedation in order to assess utilization and the effect on magnetic resonance (MR) imaging examinations.
A database of conscious sedation records for MR imaging at the Johns Hopkins Hospital, Baltimore, Md, from 1991 to 1998 was searched. Safety data according to medication and procedure duration for each nurse were tabulated for 6,093 patient records. Data were analyzed by using quality control statistical measures to determine time utilization and effectiveness. Break-even costs for the procedure were determined.
Of 6,093 patients scheduled for examination, 4,761 patients (78.1%) received conscious sedation by the MR conscious sedation service. Complications were observed in 20 of the 4,761 patients (0.42%). No deaths occurred. The most common complication was oxygen desaturation (n = 8). Diagnostic and complete MR examinations were performed in 4,453 of the 4,761 patients (93.5%). The mean time to sedate the patient (+/- SD) was 23.6 minutes +/- 15.2 for specialized MR sedation nurses and 26.8 minutes +/- 20.1 for general radiology nurses (P: <.001). For inpatient nurses from the inpatient hospital units, the sedation time was considerably longer (47.3 minutes +/- 36.6, P: <.001) and more variable. Break-even costs were 37% ($11 vs $8 for MR room time) more for general radiology nurses than for specialized MR sedation nurses performing the procedure.
Conscious sedation is safe and has a high effectiveness rate. A highly specialized nursing staff reduces procedure variability and cost.
测量清醒镇静的安全性和有效性,以评估其应用情况及对磁共振(MR)成像检查的影响。
检索了1991年至1998年马里兰州巴尔的摩市约翰·霍普金斯医院的MR成像清醒镇静记录数据库。为6093份患者记录列出了每位护士根据用药和操作时长的安全数据。采用质量控制统计方法分析数据,以确定时间利用率和有效性。确定了该操作的收支平衡成本。
在计划进行检查的6093例患者中,4761例患者(78.1%)接受了MR清醒镇静服务。4761例患者中有20例(0.42%)出现并发症。无死亡病例。最常见的并发症是氧饱和度降低(n = 8)。4761例患者中有4453例(93.5%)完成了诊断性和完整的MR检查。专业MR镇静护士使患者镇静的平均时间(±标准差)为23.6分钟±15.2分钟,普通放射科护士为26.8分钟±20.1分钟(P <.001)。对于住院部的住院护士,镇静时间明显更长(47.3分钟±36.6分钟,P <.001)且更具变异性。普通放射科护士进行该操作的收支平衡成本比专业MR镇静护士高37%(MR室时间分别为11美元和8美元)。
清醒镇静安全且有效率高。高度专业化的护理人员可降低操作变异性和成本。