Suppr超能文献

超高效液相色谱-串联质谱法同时测定人胎盘组织中防腐剂、双酚类和烷基酚类物质

Simultaneous determination of parabens, bisphenols and alkylphenols in human placenta by ultra-high performance liquid chromatography-tandem mass spectrometry.

机构信息

Sciensano, Chemical and physical health risks, 1050 Brussels, Belgium.

Center for Environmental Sciences, Hasselt University, 3500 Hasselt, Belgium.

出版信息

J Chromatogr B Analyt Technol Biomed Life Sci. 2019 Jul 15;1121:96-102. doi: 10.1016/j.jchromb.2019.05.012. Epub 2019 May 14.

Abstract

This study presents de development and validation of an ultra- high performance liquid chromatography - tandem mass spectrometry (UHPLC-MS/MS) method for the simultaneous determination of four parabens (methyl-, ethyl-, propyl-, and butyl-paraben (MeP, EtP, PrP, BuP), four bisphenols (BP) (BPA, BPB, BPF, and BPS) and two alkylphenols (nonyl phenol (NP) and tert-octylphenol (OP) in human placenta samples. After a short sample preparation time the extracts are analysed by UHPLC-MS/MS using negative electrospray ionization. Labeled internal standards and matrix-matched calibration are used for quantification of the compounds. The method was validated according FDA guideline for bio analytical methods using spiked samples at three concentration levels (0.5-5 and 25 ng g). The parameters accuracy and precision fulfill the criteria. Calibration curves are linear between 0.5 and 50 ng . The limits of detection and quantification are in the range of 0.1-0.3 ng g and 0.2-0.7 ng g, respectively. The applicability of the method was demonstrated on 71 human placenta samples from a Belgian cohort. The detection frequency was highest for OP (95%), EtP (86%), BPA (49%) and BPS (44%). Among the quantified compounds the highest quantification frequency was observed for OP (85%), EtP (65%) and BPA (25%). The concentrations of parabens ranged from 0.5 to 7.1 ng g for MeP, from 0.5 to 4.5 ng g for EtP and from 0.5 to 9.1 ng g for PrP. The levels of bisphenols ranged from 0.5 to 3.9 ng g for BPA, from 0.6 to 2.1 ng g for BPF and from 0.8 to 1.3 ng g for BPS. BPB and NP were not detected and OP levels ranged from 0.5 to 3.7 ng g g. The results demonstrate that the developed analytical method is very sensitive and that levels of several compounds with known /suspected endocrine disrupting properties could be detected or quantified in human placenta samples. The results therefore suggest that fetal exposure to these compounds occurs. The method will be useful for studies to evaluate the health effects associated with this prenatal exposure.

摘要

本研究建立了一种超高效液相色谱-串联质谱(UHPLC-MS/MS)方法,用于同时测定人胎盘样品中的四种对羟基苯甲酸酯(甲基-、乙基-、丙基-和丁基对羟基苯甲酸酯(MeP、EtP、PrP 和 BuP)、四种双酚(BPA、BPB、BPF 和 BPS)和两种烷基酚(壬基酚(NP)和叔辛基酚(OP)。在经过短暂的样品制备时间后,采用负电喷雾电离,通过 UHPLC-MS/MS 对提取物进行分析。使用标记的内标物和基质匹配校准进行化合物定量。该方法按照 FDA 生物分析方法指南进行验证,采用三个浓度水平(0.5-5 和 25ng/g)进行加标样品测定。准确度和精密度参数符合标准。校准曲线在 0.5 至 50ng/g 之间呈线性。检测限和定量限分别在 0.1-0.3ng/g 和 0.2-0.7ng/g 范围内。该方法在比利时队列的 71 个人胎盘样本中得到了应用。OP(95%)、EtP(86%)、BPA(49%)和 BPS(44%)的检测频率最高。在所定量的化合物中,OP(85%)、EtP(65%)和 BPA(25%)的定量频率最高。对羟基苯甲酸酯的浓度范围为 MeP 为 0.5 至 7.1ng/g,EtP 为 0.5 至 4.5ng/g,PrP 为 0.5 至 9.1ng/g。双酚的浓度范围为 BPA 为 0.5 至 3.9ng/g,BPF 为 0.6 至 2.1ng/g,BPS 为 0.8 至 1.3ng/g。BPB 和 NP 未检出,OP 的浓度范围为 0.5 至 3.7ng/g。结果表明,所开发的分析方法非常灵敏,能够检测或定量分析人胎盘样品中几种具有已知/疑似内分泌干扰特性的化合物。因此,研究结果表明胎儿会接触到这些化合物。该方法将有助于评估与这种产前暴露相关的健康影响的研究。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验