Suppr超能文献

使用 F-氟脱氧葡萄糖正电子发射断层扫描/计算机断层扫描对感染性心内膜炎进行亚型诊断:一项当代荟萃分析。

Diagnosis of Infective Endocarditis by Subtype Using F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography: A Contemporary Meta-Analysis.

机构信息

Section of Cardiovascular Imaging, Robert and Suzanne Tomsich Department of Cardiovascular Medicine, Sydell and Arnold Miller Family Heart, Vascular and Thoracic Institute, Cleveland Clinic, OH (T.K.M.W., P.C., B.G., B.X.).

Department of Medicine, Advocate Illinois Masonic Medical Center, Chicago (A.S.N., E.I.).

出版信息

Circ Cardiovasc Imaging. 2020 Jun;13(6):e010600. doi: 10.1161/CIRCIMAGING.120.010600. Epub 2020 Jun 8.

Abstract

Background Infective endocarditis (IE) remains a difficult to diagnose condition associated with high mortality. F-fluorodeoxyglucose positron emission tomography/computed tomography (F-FDG PET/CT) has recently emerged as another IE imaging modality, although diagnostic accuracy varies across observational studies and types of IE. This meta-analysis assessed the diagnostic performance of F-FDG PET/CT for IE and its subtypes. Methods We searched Pubmed, Cochrane, and Embase from January 1980 to September 2019 for studies reporting both sensitivity and specificity of F-FDG PET/CT for IE. Meta-Disc 1.4 was used to pool data for all cases of IE and its subgroups of native valve IE, prosthetic valve IE, and cardiac implantable electronic devices IE. Results We screened 2566 records from the search, assessed 52 full-text articles, and included 26 studies totaling 1358 patients (509 IE cases). Pooled sensitivity and specificity (95% CI, inconsistency I-square statistic) were 0.74 (0.70-0.77, 71.5%) and 0.88 (0.86-0.91, 78.5%) for all cases of endocarditis. Corresponding parameters for native valve IE were sensitivity 0.31 (0.21-0.41, 29.4%) and specificity 0.98 (0.95-0.99, 34.4%); for prosthetic valve IE: sensitivity 0.86 (0.81-0.89, 60.0%) and specificity 0.84 (0.79-0.88, 75.2%); and for cardiac implantable electronic devices IE: sensitivity 0.72 (0.61-0.81, 76.2%) and specificity 0.83 (0.75-0.89, 83.6%). Pooled sensitivities and specificities were higher for the 17 studies since 2015 than the 9 studies published before 2015. Conclusions F-FDG PET/CT had high specificity for all IE subtypes; however, sensitivity was markedly lower for native valve IE than prosthetic valve IE and cardiac implantable electronic devices IE. It is, therefore, a useful adjunct modality for assessing endocarditis, especially in the challenging scenarios of prosthetic valve IE and cardiac implantable electronic devices IE, with improving performance over time, related to advances in F-FDG PET/CT techniques.

摘要

背景

感染性心内膜炎(IE)仍然是一种难以诊断的疾病,死亡率较高。氟代脱氧葡萄糖正电子发射断层扫描/计算机断层扫描(F-FDG PET/CT)最近已成为另一种 IE 成像方式,尽管其诊断准确性因观察性研究和 IE 类型而异。本荟萃分析评估了 F-FDG PET/CT 对 IE 及其亚型的诊断性能。

方法

我们从 1980 年 1 月至 2019 年 9 月在 Pubmed、Cochrane 和 Embase 上检索了同时报告 F-FDG PET/CT 对 IE 及其亚组(原生瓣膜 IE、人工瓣膜 IE 和心脏植入式电子设备 IE)的敏感性和特异性的研究。使用 Meta-Disc 1.4 对所有 IE 病例及其亚组(原生瓣膜 IE、人工瓣膜 IE 和心脏植入式电子设备 IE)的数据进行合并。

结果

我们从搜索中筛选出 2566 条记录,评估了 52 篇全文文章,并纳入了 26 项研究,共纳入 1358 名患者(509 例 IE 病例)。所有 IE 病例的汇总敏感性和特异性(95%CI,不一致 I 平方统计)分别为 0.74(0.70-0.77,71.5%)和 0.88(0.86-0.91,78.5%)。对于原生瓣膜 IE,相应的参数为敏感性 0.31(0.21-0.41,29.4%)和特异性 0.98(0.95-0.99,34.4%);对于人工瓣膜 IE:敏感性 0.86(0.81-0.89,60.0%)和特异性 0.84(0.79-0.88,75.2%);对于心脏植入式电子设备 IE:敏感性 0.72(0.61-0.81,76.2%)和特异性 0.83(0.75-0.89,83.6%)。自 2015 年以来的 17 项研究的汇总敏感性和特异性高于 2015 年之前发表的 9 项研究。

结论

F-FDG PET/CT 对所有 IE 亚型均具有较高的特异性;然而,与人工瓣膜 IE 和心脏植入式电子设备 IE 相比,原生瓣膜 IE 的敏感性明显较低。因此,它是一种有用的辅助检查方法,尤其适用于人工瓣膜 IE 和心脏植入式电子设备 IE 等具有挑战性的情况,随着 F-FDG PET/CT 技术的进步,其性能也在不断提高。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验