Department of Orthodontics, College of Dentistry, University of Baghdad, Bab Al Muadham, Baghdad, Iraq.
Eur J Orthod. 2024 Oct 1;46(5). doi: 10.1093/ejo/cjae048.
Retainers have the potential to detrimentally impact periodontal health and contribute to tooth decay.
To investigate periodontal health and bacterial biofilm related to Poly-Ether-Ether-Ketone (PEEK) fixed retainers as compared to Dead-soft coaxial fixed retainer (DSC).
A two-arm parallel groups single-centre randomized clinical trial.
The trial included patients whose orthodontic treatment was completed and required retainers. Participants were randomly assigned into two retainer groups: PEEK retainers, prepared by computer-aided design and manufacturing into 0.8 mm wire form, and DSC retainers. The objectives included assessing periodontal health through plaque accumulation index (PI), bleeding on probing (BOP), periodontal pocket depth (PPD), gingival index (GI), calculus index (CI), and alveolar bone height (ABH) assessment. Biofilm assessment involved bacteriological screening of aerobic, facultative anaerobic, mutans streptococci, and lactobacilli. The periodontal indices and microbiological screening as well as were assessed at the debonding stage (T0), 1-month (T1), 3-month (T3), and 6-month (T6) after the commencement of the trial, except for the ABH, which was recorded using periapical radiograph at T0 and T6.
Single blinding of participants in addition to the bacteriological specialist.
Initially, the trial enrolled 46 participants, aged between 12 and 28 years, and were randomly assigned to two groups, with 23 participants in each group. Subsequently, one participant withdrew from the trial, resulting in a total of 45 participants whose data were analysed. Assessment of the periodontal indices, excluding the CI (P = .480), revealed statistically but not clinically significant differences between groups after 6-month of retention (P = .016 of PI, P = .020 of BOP, P = .05 of PPD, and P = .01 of GI). There was slight plaque accumulation, normal PPD (approximately 1 mm), healthy to mild gingivitis with a GI of less than 1 and BOP was around 10%. Concerning the ABH, there was a noticeable reduction in its score after 6 months, particularly in the PEEK group, although the difference was not statistically significant (P = .102). Furthermore, the bacteriological viable count did not show any significant difference between the groups during the recall visits.
There have been no reported negative consequences.
Blinding the assessor of periodontal indices was not feasible due to the nature of the intervention. The trial follow-up duration was limited.
Both the PEEK and DSC retainers have comparable impacts on periodontal health and bacterial accumulation and composition during the retention period.
NCT05557136.
保持器有可能对牙周健康产生不利影响,并导致龋齿。
研究聚醚醚酮(PEEK)固定保持器与软丝双轴(DSC)固定保持器相比对牙周健康和细菌生物膜的影响。
双臂平行组单中心随机临床试验。
该试验纳入了正畸治疗完成且需要保持器的患者。参与者被随机分配到两个保持器组:PEEK 保持器,通过计算机辅助设计和制造制成 0.8mm 金属丝形式,以及 DSC 保持器。主要指标包括通过菌斑指数(PI)、探诊出血(BOP)、牙周袋深度(PPD)、牙龈指数(GI)、牙石指数(CI)和牙槽骨高度(ABH)评估牙周健康。生物膜评估包括需氧菌、兼性厌氧菌、变形链球菌和乳杆菌的细菌学筛查。除 ABH 外,在试验开始时(T0)、1 个月(T1)、3 个月(T3)和 6 个月(T6)评估牙周指数和微生物筛查,除 ABH 外,T0 和 T6 使用根尖片记录。
除细菌学专家外,对参与者进行单盲。
最初,该试验纳入了 46 名年龄在 12 至 28 岁之间的参与者,并随机分为两组,每组 23 名参与者。随后,一名参与者退出了试验,共有 45 名参与者的数据被分析。在 6 个月的保持期后,除了 CI(P=0.480)外,评估牙周指数显示组间存在统计学但无临床意义的差异(PI 的 P=0.016,BOP 的 P=0.020,PPD 的 P=0.05,GI 的 P=0.01)。有轻微的菌斑积聚,正常的 PPD(约 1mm),健康至轻度牙龈炎,GI 小于 1,BOP 约为 10%。关于 ABH,6 个月后其评分明显下降,尤其是 PEEK 组,尽管差异无统计学意义(P=0.102)。此外,在随访期间,两组之间的细菌活菌计数没有显示出任何显著差异。
没有报告负面后果。
由于干预措施的性质,对牙周指数评估者进行盲法评估是不可行的。试验随访时间有限。
在保持期内,PEEK 和 DSC 保持器对牙周健康和细菌积聚和组成的影响相当。
NCT05557136。