Suppr超能文献

筛查对比增强乳腺摄影对乳腺癌高危致密乳腺女性的诊断准确性。

Diagnostic Accuracy of Screening Contrast-enhanced Mammography for Women with Extremely Dense Breasts at Increased Risk of Breast Cancer.

机构信息

From the Department of Radiology, Memorial Sloan Kettering Cancer Center, 300 E 66th St, New York, NY 100065.

出版信息

Radiology. 2024 Oct;313(1):e232580. doi: 10.1148/radiol.232580.

Abstract

Background Mammogram interpretation is challenging in female patients with extremely dense breasts (Breast Imaging Reporting and Data System [BI-RADS] category D), who have a higher breast cancer risk. Contrast-enhanced mammography (CEM) has recently emerged as a potential alternative; however, data regarding CEM utility in this subpopulation are limited. Purpose To evaluate the diagnostic performance of CEM for breast cancer screening in female patients with extremely dense breasts. Materials and Methods This retrospective single-institution study included consecutive CEM examinations in asymptomatic female patients with extremely dense breasts performed from December 2012 to March 2022. From CEM examinations, low-energy (LE) images were the equivalent of a two-dimensional full-field digital mammogram. Recombined images highlighting areas of contrast enhancement were constructed using a postprocessing algorithm. The sensitivity and specificity of LE images and CEM images (ie, including both LE and recombined images) were calculated and compared using the McNemar test. Results This study included 1299 screening CEM examinations (609 female patients; mean age, 50 years ± 9 [SD]). Sixteen screen-detected cancers were diagnosed, and two interval cancers occured. Five cancers were depicted at LE imaging and an additional 11 cancers were depicted at CEM (incremental cancer detection rate, 8.7 cancers per 1000 examinations). CEM sensitivity was 88.9% (16 of 18; 95% CI: 65.3, 98.6), which was higher than the LE examination sensitivity of 27.8% (five of 18; 95% CI: 9.7, 53.5) ( = .003). However, there was decreased CEM specificity (88.9%; 1108 of 1246; 95% CI: 87.0, 90.6) compared with LE imaging (specificity, 96.2%; 1199 of 1246; 95% CI: 95.0, 97.2) ( < .001). Compared with specificity at baseline, CEM specificity at follow-up improved to 90.7% (705 of 777; 95% CI: 88.5, 92.7; = .01). Conclusion Compared with LE imaging, CEM showed higher sensitivity but lower specificity in female patients with extremely dense breasts, although specificity improved at follow-up. © RSNA, 2024 See also the editorial by Lobbes in this issue.

摘要

背景 乳腺影像报告和数据系统(BI-RADS)分类为 D 类的致密型乳腺女性患者的乳腺 X 线摄影检查具有挑战性,此类患者乳腺癌风险较高。对比增强乳腺 X 线摄影(CEM)最近已成为一种潜在的替代方法,但是,关于该方法在该亚人群中的应用的数据有限。目的 旨在评估 CEM 用于致密型乳腺女性患者乳腺癌筛查的诊断性能。材料与方法 本回顾性单机构研究纳入了 2012 年 12 月至 2022 年 3 月间进行的连续 CEM 检查,入组对象为无症状的致密型乳腺女性患者。CEM 检查的低能(LE)图像与二维全视野数字乳腺 X 线摄影相当。使用后处理算法构建突出对比增强区域的重组图像。使用 McNemar 检验比较 LE 图像和 CEM 图像(即包括 LE 和重组图像)的敏感性和特异性。结果 本研究纳入了 1299 例筛查性 CEM 检查(609 例女性患者;平均年龄 50 岁±9[标准差])。诊断出 16 例筛查检出的癌症,2 例为间隔期癌症。5 例癌症仅在 LE 成像中显示,另外 11 例癌症在 CEM 中显示(增量癌症检出率为每 1000 例检查 8.7 例)。CEM 的敏感性为 88.9%(18 例中的 16 例;95%CI:65.3,98.6),高于 LE 检查的敏感性 27.8%(18 例中的 5 例;95%CI:9.7,53.5)( =.003)。但是,CEM 的特异性(88.9%;1246 例中的 1108 例;95%CI:87.0,90.6)较 LE 成像(特异性,96.2%;1246 例中的 1199 例;95%CI:95.0,97.2)有所降低( <.001)。与基线时的特异性相比,随访时 CEM 的特异性提高至 90.7%(777 例中的 705 例;95%CI:88.5,92.7; =.01)。结论 与 LE 成像相比,在致密型乳腺女性患者中,CEM 检查的敏感性较高,但特异性较低,但是,在随访时特异性会提高。©RSNA,2024 另请参阅本期 Lobbes 医生的述评。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验