Suppr超能文献

采用峰聚焦的在线柱切换自动高效液相色谱-串联质谱法测定尿液中的九种环境酚类物质。

Automated on-line column-switching HPLC-MS/MS method with peak focusing for the determination of nine environmental phenols in urine.

作者信息

Ye Xiaoyun, Kuklenyik Zsuzsanna, Needham Larry L, Calafat Antonia M

机构信息

Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, Atlanta, GA 30341, USA.

出版信息

Anal Chem. 2005 Aug 15;77(16):5407-13. doi: 10.1021/ac050390d.

Abstract

We developed a method using isotope dilution on-line solid-phase extraction (SPE) coupled to high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) for the determination in urine of nine environmental phenolic compounds: Bisphenol A; 4-tert-octylphenol; o-phenylphenol; 2,4-dichlorophenol; 2,5-dichlorophenol; 2,4,5-trichlorophenol; 2,4,6-trichlorophenol; benzophenone-3 (2-hydroxy-4-metoxybenzophenone); and triclosan (2,4,4'-trichloro-2'-hydroxyphenyl ether). A unique fully automated column-switching system, constructed using 1 autosampler, 2 HPLC pumps, and a 10-port switching valve, was designed to allow for concurrent SPE-HPLC operation with peak focusing. The phenols present in 100 microL of urine were retained and concentrated on a C18 reversed-phase size-exclusion SPE column. Then, the phenols were "back-eluted" from the SPE column and diluted through a mixing Tee before being separated from other urine matrix components using a pair of monolithic HPLC columns. The phenols were detected by negative ion-atmospheric pressure chemical ionization-MS/MS. The efficient preconcentration of the phenols by the SPE column, analyte peak focusing by the dilution, and minimal ion suppression in the LC/MS interface by the buffer-free mobile phases resulted in limits of detection as low as 0.1-0.4 ng/mL for most analytes. The method was validated on spiked pooled urine samples and on urine samples from 30 adults with no known occupational exposure to environmental phenols. The method can be used for quick and accurate analysis of large numbers of samples in epidemiologic studies for assessing the prevalence of human exposure to environmental phenols.

摘要

我们开发了一种方法,该方法采用同位素稀释在线固相萃取(SPE)与高效液相色谱 - 串联质谱(HPLC - MS/MS)联用,用于测定尿液中的九种环境酚类化合物:双酚A;4 - 叔辛基苯酚;邻苯基苯酚;2,4 - 二氯苯酚;2,5 - 二氯苯酚;2,4,5 - 三氯苯酚;2,4,6 - 三氯苯酚;二苯甲酮 - 3(2 - 羟基 - 4 - 甲氧基二苯甲酮);以及三氯生(2,4,4'-三氯 - 2'-羟基苯基醚)。设计了一种独特的全自动柱切换系统,该系统使用1个自动进样器、2个HPLC泵和一个10通切换阀构建而成,可实现同时进行SPE - HPLC操作及峰聚焦。100微升尿液中的酚类化合物被保留并浓缩在C18反相尺寸排阻SPE柱上。然后,酚类化合物从SPE柱上“反洗脱”,并通过混合三通进行稀释,随后使用一对整体式HPLC柱与其他尿液基质成分分离。酚类化合物通过负离子大气压化学电离 - MS/MS进行检测。SPE柱对酚类化合物的高效预浓缩、稀释导致的分析物峰聚焦以及无缓冲流动相在LC/MS接口中产生的最小离子抑制,使得大多数分析物的检测限低至0.1 - 0.4纳克/毫升。该方法在加标混合尿液样本以及来自30名无已知职业性接触环境酚类化合物的成年人的尿液样本上进行了验证。该方法可用于流行病学研究中对大量样本进行快速准确的分析,以评估人类接触环境酚类化合物的普遍性。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验