Department of Gastroenterology and Hepatology, National Center for Global Health and Medicine, Shinjuku, Tokyo 162-8655, Japan.
World J Gastroenterol. 2013 Apr 21;19(15):2362-7. doi: 10.3748/wjg.v19.i15.2362.
To identify the diagnostic value of colonoscopy for diverticulosis as determined by barium enema.
A total of 65 patients with hematochezia who underwent colonoscopy and barium enema were analyzed, and the diagnostic value of colonoscopy for diverticula was assessed. The receiver operating characteristic area under the curve was compared in relation to age (< 70 or ≥ 70 years), sex, and colon location. The number of diverticula was counted, and the detection ratio was calculated.
Colonic diverticula were observed in 46 patients with barium enema. Colonoscopy had a sensitivity of 91% and specificity of 90%. No significant differences were found in the receiver operating characteristic area under the curve (ROC-AUC) for age group or sex. The ROC-AUC of the left colon was significantly lower than that of the right colon (0.81 vs 0.96, P = 0.02). Colonoscopy identified 486 colonic diverticula, while barium enema identified 1186. The detection ratio for the entire colon was therefore 0.41 (486/1186). The detection ratio in the left colon (0.32, 189/588) was significantly lower than that of the right colon (0.50, 297/598) (P < 0.01).
Compared with barium enema, only half the number of colonic diverticula can be detected by colonoscopy in the entire colon and even less in the left colon.
通过钡剂灌肠来确定结肠镜对憩室病的诊断价值。
对 65 例便血行结肠镜和钡剂灌肠检查的患者进行分析,评估结肠镜对憩室的诊断价值。比较年龄(<70 岁或≥70 岁)、性别和结肠部位对受试者工作特征曲线下面积(ROC-AUC)的影响。计数憩室数量,并计算检出率。
钡剂灌肠检查发现 46 例患者有结肠憩室。结肠镜的敏感性为 91%,特异性为 90%。年龄组或性别组的 ROC-AUC 无显著差异。左半结肠的 ROC-AUC 明显低于右半结肠(0.81 比 0.96,P=0.02)。结肠镜共检出 486 个结肠憩室,而钡剂灌肠检查检出 1186 个。因此,整个结肠的检出率为 0.41(486/1186)。左半结肠(0.32,189/588)的检出率明显低于右半结肠(0.50,297/598)(P<0.01)。
与钡剂灌肠相比,结肠镜在整个结肠中仅能检出一半数量的结肠憩室,在左半结肠中检出的数量更少。