放射治疗不会损害头颈部癌症患者牙本质的黏附性能。

Radiotherapy does not impair dentin adhesive properties in head and neck cancer patients.

机构信息

Department of Restorative Dentistry, Piracicaba Dental School, University of Campinas-UNICAMP, Limeira Avenue, 901-Piracicaba, São Paulo, Brazil, 13414-903, 52.

出版信息

Clin Oral Investig. 2014 Sep;18(7):1771-8. doi: 10.1007/s00784-013-1155-4. Epub 2013 Dec 6.

Abstract

OBJECTIVES

This study evaluated the influence of radiotherapy on the dentin bond strength of teeth extracted from patients who had undergone head and neck radiotherapy.

MATERIALS AND METHODS

A total of 36 samples were divided into two experimental groups: group I (control group, n = 18) and group II (in vivo irradiated group, n = 18). Groups I and II were further separated into three subgroups (six specimens per subgroup), which were further assigned to the three adhesive system protocols employed: Single Bond 2 (SB) (3M ESPE), Easy Bond (EB) (3M ESPE) and Clearfil SE Bond (CSE) (Kuraray). The adhesive systems were applied to the prepared surface according to the manufacturers' instructions and restored using composite resin (Filtek Supreme, 3M ESPE). After 24 h in deionised water (37(o)C), teeth were horizontally and vertically cut to obtain beam specimens with a cross-section area of 0.8 ± 1.0 mm(2). Specimens were tested in tension using a universal testing machine at a cross-speed of 0.5 mm/min. Fracture patterns were observed under SEM. Data was analysed by two-way analysis of variance (p ≤ 0.05).

RESULTS

No statistically significant difference was found between the irradiated (R/SB = 44.66 ± 10.12 MPa; R/EB = 41.48 ± 12.71 MPa; and R/CSE = 46.01 ± 6.98 MPa) and control group (C/SB = 39.12 ± 9.51 MPa; C/EB = 42.40 ± 6.66 MPa; and C/CSE = 36.58 ± 7.06 MPa) for any of the adhesive systems. All groups presented a predominance of mixed fracture modes.

CONCLUSION

Head and neck radiotherapy did not affect dentin bond strength for the adhesive materials tested in this study.

摘要

目的

本研究评估了头颈部放疗患者拔牙后的牙本质粘结强度受放疗影响的情况。

材料与方法

共 36 个样本分为两组实验:实验组 I(对照组,n=18)和实验组 II(体内照射组,n=18)。两组进一步分为三个亚组(每组 6 个样本),并进一步分为三组粘结系统方案:Single Bond 2(SB)(3M ESPE)、Easy Bond(EB)(3M ESPE)和 Clearfil SE Bond(CSE)(Kuraray)。根据制造商的说明将粘结系统应用于准备好的表面,并用复合树脂(Filtek Supreme,3M ESPE)修复。在去离子水(37℃)中 24 h 后,将牙齿水平和垂直切割,获得横截面面积为 0.8±1.0 mm2 的梁样本。使用万能试验机以 0.5 mm/min 的十字速度进行拉伸测试。在 SEM 下观察断裂模式。数据通过双因素方差分析(p≤0.05)进行分析。

结果

对于任何粘结系统,照射组(R/SB=44.66±10.12 MPa;R/EB=41.48±12.71 MPa;R/CSE=46.01±6.98 MPa)与对照组(C/SB=39.12±9.51 MPa;C/EB=42.40±6.66 MPa;C/CSE=36.58±7.06 MPa)之间均无统计学差异。所有组均以混合断裂模式为主。

结论

本研究中测试的粘结材料的头颈部放疗未影响牙本质粘结强度。