Suppr超能文献

[多焦点人工晶状体附加镜片的临床结果]

[Clinical results of a multifocal pseudophakic additional lens].

作者信息

Schrecker J, Langenbucher A

机构信息

Klinik für Augenheilkunde, Rudolph-Virchow-Klinikum Glauchau, Virchowstr. 18, 08371, Glauchau, Deutschland,

出版信息

Ophthalmologe. 2015 Feb;112(2):148-54. doi: 10.1007/s00347-014-3102-4.

Abstract

BACKGROUND

In order to meet the patients wish for compensation of presbyopia in a flexible way, even in cases of an already pseudophacic eye, sulcus-fixated additional intraocular lenses (IOL) have been developed as an alternative to multifocal IOLs (MIOL) in the capsular bag. This allows subsequent application of multifocal optics. Furthermore, these additional lenses offer a relatively simple opportunity for postoperative refractive fine tuning or, in cases of incompatibility, a minimally invasive explantation of the multifocal part of the optical system.

PURPOSE

The objective of our work was the examination of a diffractive multifocal additional IOL and its functional characteristics.

MATERIAL AND METHODS

In a prospective, monocentric trial 32 eyes of 21 patients had cataract surgery with implantation of a monofocal IOL into the capsular bag and simultaneous implantation of a multifocal additional IOL into the sulcus. The visual acuity was tested at different distances 6 weeks and 3 months postoperatively. At the 3 month follow-up contrast sensitivity and defocus curves were additionally assessed. Patients with bilateral implantation filled in a questionnaire to assess their subjective satisfaction of postoperative visual quality.

RESULTS

All eyes had an uneventful postoperative course. At both follow-ups an uncorrected distance and near visual acuity (VA) of 0.2 LogMAR or better was achieved. In intermediate vision 29 out of 32 eyes after 6 weeks and 31 out of 32 eyes after 3 months reached an uncorrected VA of 0.2 LogMAR or better. The defocus curves showed a typical two-peaked shape. At intermediate distance (-1.5 D of defocus) the median VA was 0.35 LogMAR. Contrast sensitivity testing showed results in the upper region of the standard range of age-matched, healthy patients.

DISCUSSION

The examined type of diffractive additional IOL achieved good to very good functional results, which are comparable to corresponding IOLs in the capsular bag. Multifocal additional IOLs can be considered as a useful extension of refractive surgical alternatives for the compensation of presbyopia. The possibility to implant the multifocal optic part independently of the primary surgery, the minimal invasivity of the procedure and the likewise time-independent reversibility can be pointed out as special qualities of these IOL.

摘要

背景

为了灵活满足患者矫正老花眼的需求,即使是对于已经植入人工晶状体的眼睛,也开发了沟固定型附加人工晶状体(IOL),作为囊袋内多焦点人工晶状体(MIOL)的替代方案。这使得后续可以应用多焦点光学元件。此外,这些附加晶状体为术后屈光微调提供了相对简单的机会,或者在不相容的情况下,为光学系统的多焦点部分提供了微创取出的方法。

目的

我们研究的目的是检查一种衍射多焦点附加人工晶状体及其功能特性。

材料与方法

在一项前瞻性单中心试验中,21例患者的32只眼睛接受了白内障手术,在囊袋内植入单焦点人工晶状体,并同时在沟内植入多焦点附加人工晶状体。术后6周和3个月时在不同距离测试视力。在3个月随访时,还评估了对比敏感度和散焦曲线。双侧植入的患者填写问卷以评估他们对术后视觉质量的主观满意度。

结果

所有眼睛术后过程均顺利。在两次随访中,未矫正的远视力和近视力(VA)均达到0.2 LogMAR或更好。在中距离视力方面,6周后32只眼中的29只和3个月后32只眼中的31只未矫正VA达到0.2 LogMAR或更好。散焦曲线呈现典型的双峰形状。在中距离(-1.5 D散焦)时,平均VA为0.35 LogMAR。对比敏感度测试结果处于年龄匹配的健康患者标准范围的较高区域。

讨论

所检查的衍射附加人工晶状体类型取得了良好至非常好的功能结果,与囊袋内相应的人工晶状体相当。多焦点附加人工晶状体可被视为矫正老花眼的屈光手术替代方案的有用扩展。可以指出,这些人工晶状体的特殊优点包括能够独立于初次手术植入多焦点光学部分、手术微创性以及同样与时间无关的可逆性。