Suppr超能文献

警报通知系统对关键检验结果闭环沟通的四年影响。

Four-year impact of an alert notification system on closed-loop communication of critical test results.

作者信息

Lacson Ronilda, Prevedello Luciano M, Andriole Katherine P, O'Connor Stacy D, Roy Christopher, Gandhi Tejal, Dalal Anuj K, Sato Luke, Khorasani Ramin

机构信息

1 Center for Evidence-Based Imaging, Brigham and Women's Hospital, 1620 Tremont St, 3rd Fl, Boston, MA 02120.

出版信息

AJR Am J Roentgenol. 2014 Nov;203(5):933-8. doi: 10.2214/AJR.14.13064.

Abstract

OBJECTIVE

One of the patient safety goals proposed by the Joint Commission urges hospitals to develop a policy for communicating critical test results and to measure adherence to that policy. We evaluated the impact of an alert notification system on policy adherence for communicating critical imaging test results to referring providers and assessed system adoption over the first 4 years after implementation.

MATERIALS AND METHODS

This study was performed in a 753-bed academic medical center. The intervention, an automated alert notification system for critical results, was implemented in January 2010. The primary outcome was adherence to institutional policy for timely closed-loop communication of critical imaging results, and the secondary outcome was system adoption. Policy adherence was determined through manual review of a random sample of radiology reports from the first 4 years after the intervention (n = 37,604) compared with baseline outcomes 1 year before the intervention (n = 9430). Adoption was evaluated by quantifying the use of the system overall and the proportion of alerts that used noninterruptive communication as a percentage of all reports generated by 320 radiologists (n = 1,538,059). A statistical analysis of the trend at 6-month intervals over 4 years was performed using a chi-square trend test.

RESULTS

Adherence to the policy increased from 91.3% before the intervention to 95.0% after the intervention (p < 0.0001). There was a ninefold increase in the critical results communicated via the system (chi-square trend test, p < 0.0001). During the first 4 years after the intervention, 41,445 alerts (41% of the total number of alerts) used the system's noninterruptive process for communicating less urgent critical results, which was substantially unchanged over the 4 years postintervention, thus reducing unnecessary paging interruptions.

CONCLUSION

An automated alert notification system for communicating critical imaging results was successfully adopted and was associated with increased adherence to institutional policy for communicating critical test results and with reduced workflow interruptions.

摘要

目的

联合委员会提出的患者安全目标之一,敦促医院制定一项关于传达关键检查结果的政策,并衡量对该政策的遵守情况。我们评估了警报通知系统对向转诊医生传达关键影像检查结果的政策遵守情况的影响,并评估了实施后头4年该系统的采用情况。

材料与方法

本研究在一家拥有753张床位的学术医疗中心进行。干预措施是在2010年1月实施的用于关键结果的自动警报通知系统。主要结果是对关键影像结果进行及时闭环沟通的机构政策的遵守情况,次要结果是系统采用情况。通过人工审查干预后前4年(n = 37,604)放射学报告的随机样本,并与干预前1年的基线结果(n = 9,430)进行比较,确定政策遵守情况。通过量化系统的总体使用情况以及使用非干扰性沟通的警报在320名放射科医生生成的所有报告(n = 1,538,059)中所占的比例,来评估采用情况。使用卡方趋势检验对4年中每6个月间隔的趋势进行统计分析。

结果

干预前政策遵守率为91.3%,干预后升至95.0%(p < 0.0001)。通过该系统传达的关键结果增加了九倍(卡方趋势检验,p < 0.0001)。在干预后的头4年中,41,445条警报(占警报总数的41%)使用了该系统的非干扰性流程来传达不太紧急的关键结果,在干预后的4年中基本保持不变,从而减少了不必要的传呼干扰。

结论

用于传达关键影像结果的自动警报通知系统成功得到采用,并与提高对传达关键检查结果的机构政策的遵守情况以及减少工作流程干扰相关。

相似文献

1
Four-year impact of an alert notification system on closed-loop communication of critical test results.
AJR Am J Roentgenol. 2014 Nov;203(5):933-8. doi: 10.2214/AJR.14.13064.
6
Impact of a 4-year quality improvement initiative to improve communication of critical imaging test results.
Radiology. 2011 Jun;259(3):802-7. doi: 10.1148/radiol.11101396. Epub 2011 Apr 5.
7
Semiautomated System for Nonurgent, Clinically Significant Pathology Results.
Appl Clin Inform. 2018 Apr;9(2):411-421. doi: 10.1055/s-0038-1654700. Epub 2018 Jun 6.
9
The RADCAT-3 system for closing the loop on important non-urgent radiology findings: a multidisciplinary system-wide approach.
Emerg Radiol. 2017 Apr;24(2):119-125. doi: 10.1007/s10140-016-1452-8. Epub 2016 Oct 14.
10
The impact of real-time clinical alerts on the compliance of anesthesia documentation: A retrospective observational study.
Comput Methods Programs Biomed. 2020 Jul;191:105399. doi: 10.1016/j.cmpb.2020.105399. Epub 2020 Feb 28.

引用本文的文献

1
Theory of radiologist interaction with instant messaging decision support tools: A sequential-explanatory study.
PLOS Digit Health. 2024 Feb 26;3(2):e0000297. doi: 10.1371/journal.pdig.0000297. eCollection 2024 Feb.
3
Increasing Utilization and Improving Documentation in a Radiology Critical Alert System.
Curr Probl Diagn Radiol. 2023 Jul-Aug;52(4):230-232. doi: 10.1067/j.cpradiol.2023.03.013. Epub 2023 Mar 22.
5
Incidental Pulmonary Nodules - What Do We Know in 2022.
Respiration. 2022;101(11):1024-1034. doi: 10.1159/000526818. Epub 2022 Oct 13.
7
A Feasibility Study of Expanded Home-Based Telerehabilitation After Stroke.
Front Neurol. 2021 Feb 3;11:611453. doi: 10.3389/fneur.2020.611453. eCollection 2020.
8
Effect of COVID-19 on computed tomography usage and critical test results in the emergency department: an observational study.
CMAJ Open. 2020 Sep 14;8(3):E568-E576. doi: 10.9778/cmajo.20200148. Print 2020 Jul-Sep.
9
Variation in electronic test results management and its implications for patient safety: A multisite investigation.
J Am Med Inform Assoc. 2020 Aug 1;27(8):1214-1224. doi: 10.1093/jamia/ocaa093.
10
Delayed Diagnosis Is the Primary Cause of Sarcoma Litigation: Analysis of Malpractice Claims in the United States.
Clin Orthop Relat Res. 2020 Oct;478(10):2239-2253. doi: 10.1097/CORR.0000000000001340.

本文引用的文献

1
An initiative to improve the management of clinically significant test results in a large health care network.
Jt Comm J Qual Patient Saf. 2013 Nov;39(11):517-27. doi: 10.1016/s1553-7250(13)39068-0.
2
Impact of an automated email notification system for results of tests pending at discharge: a cluster-randomized controlled trial.
J Am Med Inform Assoc. 2014 May-Jun;21(3):473-80. doi: 10.1136/amiajnl-2013-002030. Epub 2013 Oct 23.
3
Primary care closed claims experience of Massachusetts malpractice insurers.
JAMA Intern Med. 2013;173(22):2063-8. doi: 10.1001/jamainternmed.2013.11070.
4
Ten key considerations for the successful implementation and adoption of large-scale health information technology.
J Am Med Inform Assoc. 2013 Jun;20(e1):e9-e13. doi: 10.1136/amiajnl-2013-001684. Epub 2013 Apr 18.
5
Retrieval of radiology reports citing critical findings with disease-specific customization.
Open Med Inform J. 2012;6:28-35. doi: 10.2174/1874431101206010028. Epub 2012 Aug 10.
6
Information from Searching Content with an Ontology-Utilizing Toolkit (iSCOUT).
J Digit Imaging. 2012 Aug;25(4):512-9. doi: 10.1007/s10278-012-9463-9.
7
Diagnostic error: the hidden epidemic.
Physician Exec. 2011 Nov-Dec;37(6):12-4, 16, 18-9.
9
Critical finding capture in the impression section of radiology reports.
AMIA Annu Symp Proc. 2011;2011:465-9. Epub 2011 Oct 22.
10

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。