Suppr超能文献

股内侧肌神经测量的可靠性:对研究与实践的启示

The Reliability of Neurological Measurement in the Vastus Medialis: Implications for Research and Practice.

作者信息

Leung Hans, Latella Christopher, Lamon Séverine, Hendy Ashlee M

机构信息

School of Exercise and Nutrition Sciences, Institute for Physical Activity and Nutrition (IPAN), Deakin University, Geelong, VIC, Australia.

出版信息

Front Psychol. 2018 Oct 1;9:1857. doi: 10.3389/fpsyg.2018.01857. eCollection 2018.

Abstract

The integrity of the corticomotor pathway is paramount in the optimal functioning of skeletal muscle. However, variability of neurophysiological assessment via peripheral nerve and transcranial magnetic stimulation can render interpretation difficult. Seldom evidence exists regarding the reliability of such measurements in the leg extensors, which have important locomotive and functional roles. This study aimed to assess the test-retest reliability of peripheral, corticospinal and intracortical responses in the vastus medialis. Transcranial magnetic and direct current electrical nerve stimulation were delivered to sixteen healthy young adults (8M and 8F) on two separate occasions. The Hoffmann reflex, maximal compound wave, motor evoked potential, corticospinal silent period, intracortical facilitation, and short-interval intracortical inhibition were recorded from the vastus medialis at rest, and during controlled submaximal voluntary contraction. Relative reliability was quantified using intra-class correlation coefficient (ICC2,1). Absolute reliability was quantified using standard error of measurement (SEm) and minimal detectable change (MDC). Corticospinal silent period, corticospinal silent period/motor evoked potential ratio, active motor evoked potential, maximal Hoffman reflex, and passive short-interval intracortical inhibition demonstrated "good to excellent" relative reliability (ICC ≥ 0.643). Intracortical facilitation demonstrated the lowest relative reliability (ICC = 0.420-0.908). Corticospinal silent period displayed the lowest absolute reliability (SEm ≤ 18.68%). Good reliability of the maximal compound wave, Hoffman reflex, motor evoked potential, and corticospinal silent period allow for reliable neurological evaluation of peripheral and corticospinal pathways in the vastus medialis. Future research should investigate reliability of the intracortical (short-interval intracortical inhibition and intracortical facilitation) measures by using different paired-pulse stimulus parameters. These findings hold important implications for neurophysiological assessment conducted in the leg extensor group.

摘要

皮质运动通路的完整性对于骨骼肌的最佳功能至关重要。然而,通过外周神经和经颅磁刺激进行神经生理学评估的变异性可能会使解释变得困难。关于腿部伸肌中此类测量的可靠性,几乎没有证据。腿部伸肌具有重要的运动和功能作用。本研究旨在评估股内侧肌中外周、皮质脊髓和皮质内反应的重测可靠性。对16名健康年轻成年人(8名男性和8名女性)在两个不同时间进行经颅磁刺激和直流电神经刺激。在休息时以及在受控的次最大自主收缩期间,记录股内侧肌的霍夫曼反射、最大复合波、运动诱发电位、皮质脊髓静息期、皮质内易化和短间隔皮质内抑制。使用组内相关系数(ICC2,1)量化相对可靠性。使用测量标准误差(SEm)和最小可检测变化(MDC)量化绝对可靠性。皮质脊髓静息期、皮质脊髓静息期/运动诱发电位比值、主动运动诱发电位、最大霍夫曼反射和被动短间隔皮质内抑制表现出“良好至优秀”的相对可靠性(ICC≥0.643)。皮质内易化表现出最低的相对可靠性(ICC = 0.420 - 0.908)。皮质脊髓静息期表现出最低的绝对可靠性(SEm≤18.68%)。最大复合波、霍夫曼反射、运动诱发电位和皮质脊髓静息期的良好可靠性允许对股内侧肌的外周和皮质脊髓通路进行可靠的神经学评估。未来的研究应通过使用不同的配对脉冲刺激参数来研究皮质内(短间隔皮质内抑制和皮质内易化)测量的可靠性。这些发现对腿部伸肌群的神经生理学评估具有重要意义。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/5224/6174212/f27d24262993/fpsyg-09-01857-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验