Suppr超能文献

双发射碳点作为荧光探针,通过不同的机制实现对 pH 值、汞(II)、氯离子和 Cr(VI)的比率型荧光传感。

Dually emitting carbon dots as fluorescent probes for ratiometric fluorescent sensing of pH values, mercury(II), chloride and Cr(VI) via different mechanisms.

机构信息

Key Laboratory of Comprehensive and Highly Efficient Utilization of Salt Lake Resources, Chinese Academy of Sciences, Qinghai Institute of Salt Lakes, Xining, 810008, People's Republic of China.

Qinghai Engineering and Technology Research Center of Comprehensive Utilization of Salt, Lake Resources, Xining, 810008, People's Republic of China.

出版信息

Mikrochim Acta. 2019 May 10;186(6):341. doi: 10.1007/s00604-019-3437-2.

Abstract

The authors describe the preparation of carbon dots (CDs) that display both blue (~ 410 nm) and yellow (~ 565 nm) emission peaks. The CDs was synthesized by solvothermal treatment of o-phenylenediamine in aqueous ethyl alcohol at pH ~7.0. The CDs are shown to be useful fluorescent probes for pH values in that the ratio of fluorescences at 565 and 410 nm strongly depends on the pH value in the range from 4.5-6.5 and 10.0-13.0, respectively. The blue fluorescence is quenched by 91% by 100 µM solutions of Hg(II) through an electron transfer process, and is restored by 97% an addition of chloride (0.5 mM). The yellow fluorescence, in contrast, is hardly affected. The ratio of fluorescences at 414 and 565 nm drops linearly in the 30 to 60 μM of Hg(II) concentration range, and the limit of detection is 60 nM. Fluorescence is linearly restored in the 70 to 180 μM chloride concentration range, and the LOD is 2.8 nM. Both the blue and the yellow emission are reduced by Cr(VI) (chromate) due to an inner filter effect at pH 3.0. The ratio of fluorescences (410/565 nm) drops linearly in the 20 to 250 μM Cr(VI) concentration range, and the LOD is 260 nM. The method was utilized to analysis of chloride in salt lake brine and of Cr(VI) in spiked tap water. Graphical abstract Schematic presentation of carbon dots with pH-dependent dual emission (at ~ 410 nm and ~ 565 nm). They are shown to be viable fluorescent probes for ratiometric sensing of pH values, mercury(II), chloride and Cr(VI) via different mechanisms.

摘要

作者描述了一种制备同时显示蓝色(约 410nm)和黄色(约 565nm)发射峰的碳点(CDs)的方法。该 CDs 通过在 pH 值约为 7.0 的水乙醇中溶剂热处理邻苯二胺合成。研究表明,这些 CDs 是用于 pH 值的有用荧光探针,因为在 4.5-6.5 和 10.0-13.0 范围内,565nm 和 410nm 处荧光强度的比值强烈依赖于 pH 值。蓝色荧光通过电子转移过程被 100µM 的 Hg(II) 溶液猝灭 91%,而通过添加氯离子(0.5mM)可恢复 97%。相比之下,黄色荧光几乎不受影响。在 30 至 60µM 的 Hg(II) 浓度范围内,414nm 和 565nm 处荧光强度的比值呈线性下降,检出限为 60nM。在 70 至 180µM 氯离子浓度范围内,荧光线性恢复,检出限为 2.8nM。在 pH 3.0 时,Cr(VI)(铬酸盐)由于内滤效应而同时降低蓝色和黄色发射。在 20 至 250µM 的 Cr(VI) 浓度范围内,荧光强度比值(410/565nm)呈线性下降,检出限为 260nM。该方法用于盐湖卤水氯离子和自来水 Cr(VI) 的分析。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验