Clínica Rementería, c/ Almagro no 36, entreplanta derecha, 28010, Madrid, Spain.
Int Ophthalmol. 2021 Jan;41(1):163-172. doi: 10.1007/s10792-020-01563-6. Epub 2020 Aug 25.
To report visual outcomes and patient-perceived satisfaction after trifocal or extended depth-of-focus (EDOF) intraocular lens (IOL) implantation in a real-world scenario.
Three months after bilateral cataract surgery, corrected and uncorrected visual acuity for far, intermediate and near distances and binocular defocus curves and contrast sensitivity were measured. The patients also completed the Catquest SF-9 questionnaire and reported on dysphotopsia and spectacle use.
There were 23 patients in the Symfony, 32 patients in the Finevision and 36 patients in the Panoptix group. The percentage of eyes receiving a toric IOL was 41.2%. There were no differences in uncorrected binocular visual acuities, save for near vision, which was lower in the Symfony group. Binocular defocus curves for the trifocal IOLS were almost identical, while vision achieved with the Symfony IOL was significantly lower starting at - 1.5 D defocus. Contrast sensitivity, as well as the perception of halos and glare and the difficulty for night-driving was similar for all groups, except for contrast sensitivity at 6 cycles per degree, which was lower in the Symfony group compared to both Finevision and Panoptix. For near vision, only 47.6% of the Symfony patients reported being completely spectacle-free, compared to 93.3% and 94.4% for the Finevision and Panoptix groups.
Clinically relevant differences were only detected for near vision, with lower values for EDOF IOLs. In order to achieve patient satisfaction, it is imperative to explain the results expected with each IOL; for EDOF IOLs, patients should be advised that they may require near-spectacle correction.
报告三焦点或扩展景深(EDOF)人工晶状体(IOL)植入在真实场景下的远、中、近视力和患者满意度。
白内障手术后 3 个月,测量远、中、近距矫正和未矫正视力,双眼离焦曲线和对比敏感度。患者还完成了 Catquest SF-9 问卷,并报告了畏光和眼镜使用情况。
Symfony 组 23 例,Finevision 组 32 例,Panoptix 组 36 例。接受散光 IOL 的眼比例为 41.2%。未矫正双眼视力无差异,但 Symfony 组近视力较低。三焦点 IOL 的双眼离焦曲线几乎相同,但 Symfony IOL 的视力在-1.5 D 离焦时明显较低。除了 Symfony 组在 6 周/度的对比敏感度较低外,各组的对比敏感度、光晕和眩光的感知以及夜间驾驶的难度相似。对于近视力,只有 47.6%的 Symfony 患者报告完全不戴眼镜,而 Finevision 和 Panoptix 组分别为 93.3%和 94.4%。
仅在近视力方面检测到临床相关差异,EDOF IOL 值较低。为了达到患者满意度,必须解释每种 IOL 的预期结果;对于 EDOF IOL,应告知患者他们可能需要近距眼镜矫正。