Huang Changyu, Chen Yang, Ding Haiqi, Huang Zida, Zhang Chaofan, Li Wenbo, Liu Xi, Tu Zhanhai, Zhang Wenming, Fang Xinyu
Department of Orthopedic Surgery, The First Affiliated Hospital of Fujian Medical University, Fuzhou 350000, China.
Department of Radiology and Imaging, The First Affiliated Hospital of Fujian Medical University, Fuzhou 350000, China.
J Clin Med. 2022 Jul 27;11(15):4371. doi: 10.3390/jcm11154371.
The diagnosis and treatment of periprosthetic joint infection (PJI) is complex and the use of MRI in PJI is gaining attention from orthopedic surgeons as MR technology continues to advance. This study aimed to investigate whether metal artefact reduction sequence (MARS) MRI could be used as an adjunct in the preoperative diagnosis of PJI and to explore its role in PJI debridement planning. From January 2020 to November 2021, participants with metal joint prostheses that needed to be judged for infection were prospectively enrolled. According to Musculoskeletal Infection Society standards, 31 cases were classified as infection, and 20 as non-infection. The sensitivity and specificity of MARS MRI for the diagnosis of PJI were 80.65% and 75%, respectively. In MARS MRI, the incidence of bone destruction, lamellar synovitis, and extracapsular soft tissue oedema were significantly higher in PJI than in non-PJI. Fourteen suspicious occult lesions were found in the preoperative MARS MRI in 9 cases, and the location of 9 infection lesions was confirmed intraoperatively. In conclusion, MARS MRI is an effective diagnostic tool for PJIand can provide a visual reference for preoperative surgical planning.
人工关节周围感染(PJI)的诊断和治疗较为复杂,随着磁共振(MR)技术的不断进步,MRI在PJI中的应用正受到骨科医生的关注。本研究旨在探讨金属伪影减少序列(MARS)MRI是否可作为PJI术前诊断的辅助手段,并探索其在PJI清创计划中的作用。2020年1月至2021年11月,前瞻性纳入了需要判断是否感染的金属关节假体患者。根据肌肉骨骼感染学会标准,31例被分类为感染,20例为非感染。MARS MRI诊断PJI的敏感性和特异性分别为80.65%和75%。在MARS MRI中,PJI患者的骨破坏、层状滑膜炎和关节囊外软组织水肿的发生率显著高于非PJI患者。9例患者的术前MARS MRI中发现14处可疑隐匿性病变,术中证实9处感染病变的位置。总之,MARS MRI是诊断PJI的有效工具,可为术前手术规划提供可视化参考。