Suppr超能文献

细节决定成败:住院环境中持续葡萄糖监测的应用、局限性及实施

The Devil Is in the Details: Use, Limitations, and Implementation of Continuous Glucose Monitoring in the Inpatient Setting.

作者信息

Longo Rebecca Rick, Joshi Renu

机构信息

Lahey Hospital and Medical Center-Beth Israel Lahey Health, Burlington, MA.

University of Pittsburgh Medical Center, Harrisburg, PA.

出版信息

Diabetes Spectr. 2022 Fall;35(4):405-419. doi: 10.2337/dsi22-0009. Epub 2022 Nov 15.

Abstract

Until recently, continuous glucose monitoring (CGM) systems were reserved for use in the outpatient setting or for investigational purposes in hospitalized patients. However, during the coronavirus disease 2019 pandemic, use of CGM in the inpatient setting has grown rapidly. This review outlines important details related to the accuracy, limitations, and implementation of, as well as necessary staff education for, inpatient CGM use and offers a glimpse into the future of CGM in the inpatient setting.

摘要

直到最近,连续血糖监测(CGM)系统仍仅用于门诊环境或住院患者的研究目的。然而,在2019年冠状病毒病大流行期间,CGM在住院环境中的使用迅速增加。本综述概述了与住院患者使用CGM的准确性、局限性、实施以及必要的员工培训相关的重要细节,并展望了CGM在住院环境中的未来。

相似文献

1
The Devil Is in the Details: Use, Limitations, and Implementation of Continuous Glucose Monitoring in the Inpatient Setting.
Diabetes Spectr. 2022 Fall;35(4):405-419. doi: 10.2337/dsi22-0009. Epub 2022 Nov 15.
2
Advancing the Use of CGM Devices in a Non-ICU Setting.
J Diabetes Sci Technol. 2019 Jul;13(4):674-681. doi: 10.1177/1932296818821094. Epub 2019 Jan 13.
3
Inpatient Continuous Glucose Monitoring and Glycemic Outcomes.
J Diabetes Sci Technol. 2017 Sep;11(5):1028-1035. doi: 10.1177/1932296817698499. Epub 2017 Mar 14.
4
Use and Accuracy of Inpatient CGM During the COVID-19 Pandemic: An Observational Study of General Medicine and ICU Patients.
J Diabetes Sci Technol. 2022 Sep;16(5):1136-1143. doi: 10.1177/19322968211008446. Epub 2021 May 10.
5
Expanding the horizon of continuous glucose monitoring into the future of pediatric medicine.
Pediatr Res. 2024 Nov;96(6):1464-1474. doi: 10.1038/s41390-024-03573-x. Epub 2024 Sep 21.
6
Continuous glucose monitoring in the hospital: an update in the era of COVID-19.
Curr Opin Endocrinol Diabetes Obes. 2022 Feb 1;29(1):1-9. doi: 10.1097/MED.0000000000000693.
7
CGM in the Hospital: Is It Ready for Prime Time?
Curr Diab Rep. 2022 Sep;22(9):451-460. doi: 10.1007/s11892-022-01484-x. Epub 2022 Jul 7.
8
Facilitators and Barriers to Nursing Implementation of Continuous Glucose Monitoring (CGM) in Critically Ill Patients With COVID-19.
Endocr Pract. 2021 Apr;27(4):354-361. doi: 10.1016/j.eprac.2021.01.011. Epub 2021 Jan 27.
9
Reliability of Inpatient CGM: Comparison to Standard of Care.
J Diabetes Sci Technol. 2023 Mar;17(2):329-335. doi: 10.1177/19322968211062168. Epub 2021 Dec 15.

引用本文的文献

1
The Use of Continuous Glucose Monitoring to Diagnose Stage 2 Type 1 Diabetes.
J Diabetes Sci Technol. 2025 May 30:19322968251333441. doi: 10.1177/19322968251333441.
2
Continuous Glucose Monitoring in Hospitalized Adults With Diabetic Ketoacidosis: A Prospective Open-Label Pilot Study.
J Diabetes Sci Technol. 2025 Feb 5:19322968251316887. doi: 10.1177/19322968251316887.
3
Impact of Recording Interval in Continuous Glucose Monitoring on Calculating the Metrics of Glycemic Control.
J Diabetes Sci Technol. 2025 Mar;19(2):590-592. doi: 10.1177/19322968241310892. Epub 2025 Jan 16.
6
Roadmap to the Effective Use of Continuous Glucose Monitoring: Innovation, Investigation, and Implementation.
Diabetes Spectr. 2023 Fall;36(4):327-336. doi: 10.2337/dsi23-0005. Epub 2023 Nov 15.

本文引用的文献

2
Accuracy of Continuous Glucose Monitors for Inpatient Diabetes Management.
J Diabetes Sci Technol. 2023 Sep;17(5):1252-1255. doi: 10.1177/19322968221076562. Epub 2022 Feb 7.
3
16. Diabetes Care in the Hospital: Standards of Medical Care in Diabetes-2022.
Diabetes Care. 2022 Jan 1;45(Suppl 1):S244-S253. doi: 10.2337/dc22-S016.
4
Reliability of Inpatient CGM: Comparison to Standard of Care.
J Diabetes Sci Technol. 2023 Mar;17(2):329-335. doi: 10.1177/19322968211062168. Epub 2021 Dec 15.
5
Practical implementation of remote continuous glucose monitoring in hospitalized patients with diabetes.
Am J Health Syst Pharm. 2022 Mar 7;79(6):452-458. doi: 10.1093/ajhp/zxab456.
6
The Need for Data Standards and Implementation Policies to Integrate CGM Data into the Electronic Health Record.
J Diabetes Sci Technol. 2023 Mar;17(2):495-502. doi: 10.1177/19322968211058148. Epub 2021 Nov 20.
7
Reliability of continuous glucose monitoring system in the inpatient setting.
J Clin Transl Endocrinol. 2021 Jul 7;25:100262. doi: 10.1016/j.jcte.2021.100262. eCollection 2021 Sep.
8
Use of Continuous Glucose Monitor in Critically Ill COVID-19 Patients Requiring Insulin Infusion: An Observational Study.
J Clin Endocrinol Metab. 2021 Sep 27;106(10):e4007-e4016. doi: 10.1210/clinem/dgab409.
9
Accuracy of Dexcom G6 Continuous Glucose Monitoring in Non-Critically Ill Hospitalized Patients With Diabetes.
Diabetes Care. 2021 Jul;44(7):1641-1646. doi: 10.2337/dc20-2856. Epub 2021 Jun 7.
10
Use and Accuracy of Inpatient CGM During the COVID-19 Pandemic: An Observational Study of General Medicine and ICU Patients.
J Diabetes Sci Technol. 2022 Sep;16(5):1136-1143. doi: 10.1177/19322968211008446. Epub 2021 May 10.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验