Sci Rep. 2024 Sep 16;14(1):21549. doi: 10.1038/s41598-024-72552-3.
To evaluate changes in dry eye-related parameters after posterior chamber phakic refractive lens (PC-PRL) implantation. This prospective study included 21 highly myopic patients (39 eyes) who underwent PC-PRL implantation at Lanzhou Huaxia Eye Hospital between January 2021 and June 2022, with a 3-month postoperative follow-up. In addition to routine preoperative examinations, dry eye assessments were conducted preoperatively and at 1 week, 1 month, and 3 months postoperatively. These assessments included the Ocular Surface Disease Index (OSDI) questionnaire score, non-invasive first tear break-up time (NIF-BUT), non-invasive average tear break-up time (NIA-BUT), tear meniscus height (TMH), meibomian gland loss (MGL) rate, and Schirmer I test (SIt). Repeated measures ANOVA was used to compare the differences in parameters across different time points, with pairwise comparisons conducted using the LSD-t test. After grouping, the Student's t-test was applied to compare normally distributed data, while the Mann-Whitney U test was used for non-normally distributed data. Categorical data were analyzed using the chi-square test. A total of 21 patients (39 eyes) were included, comprising 10 males (19 eyes) and 11 females (20 eyes), aged 19 to 49 years (33.76 ± 7.87). All patients completed the 3-month follow-up. Significant differences in OSDI scores were observed pre- and post-surgery (P = 0.008), with a peak at one week post-surgery (P < 0.001), then stabilizing at one and three months post-surgery. Postoperative NIF-BUT and NIA-BUT significantly decreased (P < 0.001 for both) but returned to preoperative levels within three months. There were no significant changes in TMH, MGL, or SIt postoperatively (P > 0.05). Significant differences in dry eye parameters were observed between the dry eye and control groups before and after surgery (P < 0.001). PC-PRL implantation impacts tear film stability on the ocular surface after surgery, leading to varying degrees of dry eye symptoms in patients. After surgery, all dry eye parameters return to their preoperative levels within three months.
评估后房型有晶状体眼人工晶状体(PC-PRL)植入术后干眼相关参数的变化。这项前瞻性研究纳入了 2021 年 1 月至 2022 年 6 月在兰州华夏眼科医院接受 PC-PRL 植入术的 21 名高度近视患者(39 只眼),术后随访 3 个月。除了常规术前检查外,还在术前和术后 1 周、1 个月和 3 个月进行干眼评估。这些评估包括眼表面疾病指数(OSDI)问卷评分、非侵入性泪膜破裂时间(NIF-BUT)、非侵入性平均泪膜破裂时间(NIA-BUT)、泪膜高度(TMH)、睑板腺缺失率(MGL)和 Schirmer I 试验(SIt)。采用重复测量方差分析比较不同时间点参数的差异,采用 LSD-t 检验进行两两比较。分组后,采用 Student's t 检验比较正态分布数据,采用 Mann-Whitney U 检验比较非正态分布数据。采用卡方检验分析分类数据。共纳入 21 例(39 只眼)患者,其中男 10 例(19 只眼),女 11 例(20 只眼),年龄 19~49 岁(33.76±7.87)。所有患者均完成 3 个月随访。术前和术后 OSDI 评分差异有统计学意义(P=0.008),术后 1 周达峰值(P<0.001),然后在术后 1 个月和 3 个月稳定。术后 NIF-BUT 和 NIA-BUT 显著下降(均 P<0.001),但在 3 个月内恢复到术前水平。术后 TMH、MGL 和 SIt 无明显变化(均 P>0.05)。术后干眼组和对照组的干眼相关参数差异有统计学意义(均 P<0.001)。PC-PRL 植入术后对眼表泪膜稳定性产生影响,导致患者出现不同程度的干眼症状。术后所有干眼参数均在 3 个月内恢复至术前水平。