Suppr超能文献

语后聋成年人工耳蜗使用者在安静和噪声环境下耳蜗神经健康状况与AzBio句子得分之间的关系。

The relationships between cochlear nerve health and AzBio sentence scores in quiet and noise in postlingually deafened adult cochlear implant users.

作者信息

Gao Zi, Yuan Yi, Oleson Jacob J, Mueller Christopher R, Bruce Ian C, Gifford René H, He Shuman

机构信息

Department of Otolaryngology - Head and Neck Surgery, The Ohio State University, Columbus, OH 43212.

Department of Audiology, San José State University, San José, CA 95192.

出版信息

medRxiv. 2024 Nov 18:2024.11.16.24317332. doi: 10.1101/2024.11.16.24317332.

Abstract

OBJECTIVES

This study investigated the relationships between the cochlear nerve (CN) health and sentence-level speech perception outcomes measured in quiet and noise in postlingually deafened adult cochlear implant (CI) users.

DESIGN

Study participants included 24 postlingually deafened adult CI users with a Cochlear Nucleus device. For each participant, only one ear was tested. Neural health of the CN was assessed at three or four electrode locations across the electrode array using two parameters derived from results of the electrically evoked compound action potential (eCAP). One parameter was the phase locking value (PLV) which estimated neural synchrony in the CN. The other parameter was the sensitivity of the eCAP amplitude growth function (AGF) slope to changes in the interphase gap (IPG) of biphasic electrical pulses (i.e., the IPGE). Speech perception was tested using AzBio sentences in both quiet and a ten-talker babble background noise with +5 dB and +10 dB signal-to-noise ratios (SNR). IPGE and PLV values were averaged across electrodes for each subject, both with and without weighting by the frequency importance function (FIF) of the AzBio sentences. Pearson and Spearman correlations were used to assess the pairwise relationships between the IPGE, the PLV, and age. Multiple linear regression models with AzBio score as the outcome and the PLV and the IPGE as predictors were used to evaluate the associations between the three variables while controlling for age.

RESULTS

The correlation between the IPGE and the PLV was negligible and not statistically significant. The PLV, but not the IPGE, differed significantly across electrodes, where the apical electrodes had larger PLVs (better neural synchrony) than the basal electrodes. The IPGE, but not the PLV, was significantly correlated with participant's age, where smaller IPGE values (poorer CN health) were associated with more advanced age. The PLV, but not the IPGE, was significantly associated with AzBio scores in noise, where larger PLVs predicted better speech perception in noise. Neither the PLV nor the IPGE was significantly associated with AzBio score in quiet. The result patterns remained the same regardless of whether the mean values of the IPGE and the PLV were weighted by the AzBio FIF.

CONCLUSIONS

The IPGE and the PLV quantify different aspects of CN health. The positive association between the PLV and AzBio scores suggests that neural synchrony is important for speech perception in noise in adult CI users. The lack of association between age and the PLV indicates that reduced neural synchrony in the CN is unlikely the primary factor accounting for the greater deficits in understanding speech in noise observed in elderly, as compared to younger, CI users.

摘要

目的

本研究调查了语后聋成年人工耳蜗(CI)使用者的蜗神经(CN)健康状况与在安静环境和噪声环境下测量的句子水平言语感知结果之间的关系。

设计

研究参与者包括24名使用科利耳核装置的语后聋成年CI使用者。对每位参与者仅测试一只耳朵。使用从电诱发复合动作电位(eCAP)结果得出的两个参数,在电极阵列的三或四个电极位置评估CN的神经健康状况。一个参数是锁相值(PLV),用于估计CN中的神经同步性。另一个参数是eCAP振幅增长函数(AGF)斜率对双相电脉冲相间间隙(IPG)变化的敏感性(即IPGE)。使用AzBio句子在安静环境以及有+5 dB和+10 dB信噪比(SNR)的十说话者嘈杂背景噪声中测试言语感知。对每个受试者,在有和没有根据AzBio句子的频率重要性函数(FIF)加权的情况下,将IPGE和PLV值在电极间进行平均。使用Pearson和Spearman相关性来评估IPGE、PLV与年龄之间的成对关系。以AzBio分数为结果、PLV和IPGE为预测因子的多元线性回归模型用于在控制年龄的同时评估这三个变量之间的关联。

结果

IPGE与PLV之间的相关性可忽略不计且无统计学意义。PLV在不同电极间存在显著差异,而IPGE没有,其中顶端电极的PLV值(神经同步性更好)大于基底电极处的PLV值。IPGE与参与者年龄显著相关,而PLV没有,其中较小的IPGE值(较差的CN健康状况)与更高的年龄相关。PLV与噪声环境下的AzBio分数显著相关,而IPGE没有,其中较大的PLV预示着在噪声环境下更好的言语感知。PLV和IPGE与安静环境下的AzBio分数均无显著关联。无论IPGE和PLV的平均值是否根据AzBio FIF进行加权,结果模式均保持不变。

结论

IPGE和PLV量化了CN健康状况的不同方面。PLV与AzBio分数之间的正相关表明神经同步性对成年CI使用者在噪声环境下的言语感知很重要。年龄与PLV之间缺乏关联表明,与年轻CI使用者相比,CN中神经同步性降低不太可能是导致老年CI使用者在理解噪声环境下言语方面存在更大缺陷的主要因素。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/bcd7/12234029/8c08916bef2f/nihpp-2024.11.16.24317332v2-f0001.jpg