¹⁸F-氟脱氧葡萄糖PET与⁶⁸Ga-成纤维细胞活化蛋白抑制剂PET在头颈癌中的比较:一项系统评价和荟萃分析

Comparison of F-fluorodeoxyglucose PET and Ga-fibroblast Activation Protein Inhibitor PET in Head and Neck Cancers: A Systematic Review and Meta-analysis.

作者信息

Huang Shuhui, Wang Yueqi, Huang Rui

机构信息

Department of Nuclear Medicine, West China Hospital, Sichuan University, No 37. Guoxue Alley, 610041, Chengdu, Sichuan, China.

Department of Nuclear Medicine, West China Hospital, Sichuan University, No 37. Guoxue Alley, 610041, Chengdu, Sichuan, China.

出版信息

Acad Radiol. 2025 Mar 10. doi: 10.1016/j.acra.2025.02.038.

Abstract

OBJECTIVES

This study aimed to compare the diagnostic efficiency of Ga-fibroblast activation protein inhibitor (FAPI) positron emission tomography (PET) and F-fluorodeoxyglucose (F-FDG) PET in patients with head and neck cancer (HNC).

DATA SOURCES

PubMed, Embase, Web of Science, and the Cochrane Library were used to perform a systemic search through June 26, 2024.

METHODS

Studies comparing the diagnostic value of Ga-FAPI PET and F-FDG PET in patients with HNC were included. We performed a bivariate meta-analysis of diagnostic data and a meta-analysis of the quantitative parameters. The summary receiver operating characteristic curve was plotted, and publication bias was evaluated via Egger's test.

RESULTS

The meta-analysis included 12 studies on 386 patients with HNC. Ga-FAPI PET had superior pooled sensitivity to F-FDG PET in detecting primary/recurrent tumors and distant metastases in both lesion-based analysis and patient-based analysis. Although the sensitivity of F-FDG PET for detecting lymph node metastases was greater than that of Ga-FAPI PET (0.93 [95% CI 0.83-0.97] vs. 0.82 [95% CI 0.63-0.93]), the specificity of F-FDG PET was lower than that of Ga-FAPI PET (0.36 [95% CI 0.01-0.96] vs. 0.97 [95% CI 0.53-1.00]). In addition, Ga-FAPI PET had a higher pooled mean maximum standardized uptake value for distant metastases (3.28 [95% CI 1.90-4.66]) and a higher pooled mean tumor-to-background ratio for primary/recurrent tumors (1.24 [95% CI 0.44-2.04]) than F-FDG PET.

CONCLUSION

Compared to F-FDG PET, Ga-FAPI PET has superior diagnostic accuracy in HNC lesions. Thus, Ga-FAPI PET may be a better tool for staging and restaging than F-FDG PET in patients with HNC.

摘要

目的

本研究旨在比较镓纤维母细胞激活蛋白抑制剂(FAPI)正电子发射断层扫描(PET)与氟脱氧葡萄糖(F-FDG)PET对头颈癌(HNC)患者的诊断效能。

数据来源

使用PubMed、Embase、Web of Science和Cochrane图书馆进行系统检索,截至2024年6月26日。

方法

纳入比较Ga-FAPI PET与F-FDG PET对HNC患者诊断价值的研究。我们对诊断数据进行了双变量荟萃分析,并对定量参数进行了荟萃分析。绘制了汇总的受试者工作特征曲线,并通过Egger检验评估发表偏倚。

结果

荟萃分析纳入了12项针对386例HNC患者的研究。在基于病灶的分析和基于患者的分析中,Ga-FAPI PET在检测原发性/复发性肿瘤和远处转移方面的汇总敏感性均高于F-FDG PET。虽然F-FDG PET检测淋巴结转移的敏感性高于Ga-FAPI PET(0.93 [95%CI 0.83-0.97] 对0.82 [95%CI 0.63-0.93]),但其特异性低于Ga-FAPI PET(0.36 [95%CI 0.01-0.96] 对0.97 [95%CI 0.53-1.00])。此外,Ga-FAPI PET对远处转移的汇总平均最大标准化摄取值(3.28 [95%CI 1.90-4.66])高于F-FDG PET,对原发性/复发性肿瘤的汇总平均肿瘤与背景比值(1.24 [95%CI 0.44-2.04])也高于F-FDG PET。

结论

与F-FDG PET相比,Ga-FAPI PET对HNC病灶具有更高的诊断准确性。因此,在HNC患者中,Ga-FAPI PET可能是比F-FDG PET更好的分期和再分期工具。