Abstract

Rapid antigen testing using immunochromatographic devices has become a diagnostic mainstay for detection of influenza virus and respiratory syncytial virus, the two major viruses infecting the respiratory tract. Recent studies have indicated that poor performance in the detection of the novel influenza A virus 2009 H1N1 should preclude their use. A survey of influenza diagnostic methods available on ClinMicroNet and Division C, the two ASM list servers, revealed that, despite this reported poor performance, a majority of the laboratories surveyed intend to continue to offer this testing during the current influenza season. Our two experts have been asked to consider the following question: what is the role of rapid immunochromatographic antigen testing in the laboratory diagnosis of influenza A virus infection during the current 2009 H1N1 pandemic?

摘要

使用免疫层析设备的快速抗原检测已成为检测流感病毒和呼吸道合胞病毒(感染呼吸道的两种主要病毒)的主要诊断方法。最近的研究表明,这种方法在检测新型甲型 H1N1 流感病毒方面表现不佳,因此不应使用。对 ClinMicroNet 和 ASM 列表服务器的 Division C 上可用的流感诊断方法进行的调查显示,尽管报告称该方法性能不佳,但大多数接受调查的实验室仍计划在当前流感季节继续提供此项检测。我们的两位专家被要求考虑以下问题:在当前 2009 年 H1N1 大流行期间,快速免疫层析抗原检测在甲型流感病毒感染的实验室诊断中的作用是什么?

相似文献

1
Role of rapid immunochromatographic antigen testing in diagnosis of influenza A virus 2009 H1N1 infection.
J Clin Microbiol. 2010 Jan;48(1):22-5. doi: 10.1128/JCM.02268-09. Epub 2009 Dec 9.
3
Time-dependent sensitivity of a rapid antigen test in patients with 2009 H1N1 influenza.
J Clin Microbiol. 2011 Apr;49(4):1702. doi: 10.1128/JCM.02247-10. Epub 2011 Jan 19.
5
Clinical evaluation of rapid point-of-care testing for detection of novel influenza A (H1N1) virus in a population-based study in Spain.
Clin Microbiol Infect. 2010 Sep;16(9):1358-61. doi: 10.1111/j.1469-0691.2010.03159.x. Epub 2010 Feb 16.
6
Diagnostic capacity of rapid influenza antigen test: reappraisal with experience from the 2009 H1N1 pandemic.
J Microbiol Immunol Infect. 2012 Apr;45(2):102-7. doi: 10.1016/j.jmii.2011.09.027. Epub 2011 Dec 16.
8
Analytical sensitivity of rapid influenza antigen detection tests for swine-origin influenza virus (H1N1).
J Clin Virol. 2009 Jul;45(3):205-7. doi: 10.1016/j.jcv.2009.05.034. Epub 2009 Jun 6.
9
Direct fluorescent-antibody testing followed by culture for diagnosis of 2009 H1N1 influenza A.
J Clin Microbiol. 2011 Oct;49(10):3673-4. doi: 10.1128/JCM.05255-11. Epub 2011 Aug 17.

引用本文的文献

1
Aptamer-Based Point-of-Care Devices: Emerging Technologies and Integration of Computational Methods.
Biosensors (Basel). 2023 May 22;13(5):569. doi: 10.3390/bios13050569.
2
Recent development of microfluidics-based platforms for respiratory virus detection.
Biomicrofluidics. 2023 Apr 3;17(2):024104. doi: 10.1063/5.0135778. eCollection 2023 Mar.
3
Right-Sizing Technology in the Era of Consumer-Driven Health Care.
Clin Microbiol Newsl. 2017 Aug 1;39(15):115-123. doi: 10.1016/j.clinmicnews.2017.07.001. Epub 2017 Jul 19.
4
An isothermal, label-free, and rapid one-step RNA amplification/detection assay for diagnosis of respiratory viral infections.
Biosens Bioelectron. 2017 Apr 15;90:187-194. doi: 10.1016/j.bios.2016.11.051. Epub 2016 Nov 23.
5
Advances in nanomaterials and their applications in point of care (POC) devices for the diagnosis of infectious diseases.
Biotechnol Adv. 2016 Dec;34(8):1275-1288. doi: 10.1016/j.biotechadv.2016.09.003. Epub 2016 Sep 26.
6
Evaluation of Four Commercial Multiplex Molecular Tests for the Diagnosis of Acute Respiratory Infections.
PLoS One. 2015 Jun 24;10(6):e0130378. doi: 10.1371/journal.pone.0130378. eCollection 2015.
7
Performance Characteristics of Xpert Flu/RSV XC Assay.
J Clin Microbiol. 2015 Aug;53(8):2720-1. doi: 10.1128/JCM.00972-15. Epub 2015 May 27.
9
Update on influenza diagnostics: lessons from the novel H1N1 influenza A pandemic.
Clin Microbiol Rev. 2012 Apr;25(2):344-61. doi: 10.1128/CMR.05016-11.
10
Two years after pandemic influenza A/2009/H1N1: what have we learned?
Clin Microbiol Rev. 2012 Apr;25(2):223-63. doi: 10.1128/CMR.05012-11.

本文引用的文献

1
Poor clinical sensitivity of rapid antigen test for influenza A pandemic (H1N1) 2009 virus.
Emerg Infect Dis. 2009 Oct;15(10):1662-4. doi: 10.3201/eid1510.091186.
2
Rapid antigen tests for diagnosis of pandemic (Swine) influenza A/H1N1.
Clin Infect Dis. 2009 Oct 1;49(7):1090-3. doi: 10.1086/644743.
3
Ruling out novel H1N1 influenza virus infection with direct fluorescent antigen testing.
Clin Infect Dis. 2009 Sep 15;49(6):e66-8. doi: 10.1086/644502.
5
Performance of influenza rapid point-of-care tests in the detection of swine lineage A(H1N1) influenza viruses.
Influenza Other Respir Viruses. 2009 Jul;3(4):171-6. doi: 10.1111/j.1750-2659.2009.00086.x.
6
Rapid-test sensitivity for novel swine-origin influenza A (H1N1) virus in humans.
N Engl J Med. 2009 Aug 13;361(7):728-9. doi: 10.1056/NEJMc0904264. Epub 2009 Jun 29.
7
Evaluation of multiple test methods for the detection of the novel 2009 influenza A (H1N1) during the New York City outbreak.
J Clin Virol. 2009 Jul;45(3):191-5. doi: 10.1016/j.jcv.2009.06.005. Epub 2009 Jun 16.
8
Analytical sensitivity of rapid influenza antigen detection tests for swine-origin influenza virus (H1N1).
J Clin Virol. 2009 Jul;45(3):205-7. doi: 10.1016/j.jcv.2009.05.034. Epub 2009 Jun 6.
9
Clinical performance of the 3M Rapid Detection Flu A+B Test compared to R-Mix culture, DFA and BinaxNOW Influenza A&B Test.
J Clin Virol. 2009 Jun;45(2):146-9. doi: 10.1016/j.jcv.2009.03.018. Epub 2009 May 5.
10
Longer virus shedding in influenza B than in influenza A among outpatients treated with oseltamivir.
J Infect. 2007 Sep;55(3):267-72. doi: 10.1016/j.jinf.2007.05.176. Epub 2007 Jul 2.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验