Suppr超能文献

测试疼痛 DETECT 问卷阿拉伯文版本在评估神经性疼痛中的有效性和可靠性。

Testing the validity and reliability of the Arabic version of the painDETECT questionnaire in the assessment of neuropathic pain.

机构信息

Research Center, King Fahad Medical City, Riyadh, Saudi Arabia.

Anesthesia department, King Fahad Medical City, Riyadh, Saudi Arabia.

出版信息

PLoS One. 2018 Apr 23;13(4):e0194358. doi: 10.1371/journal.pone.0194358. eCollection 2018.

Abstract

INTRODUCTION

Neuropathic pain (NP) can cause substantial suffering and, therefore, it must be diagnosed and treated promptly. Diagnosis of NP can be difficult and if made by an expert pain physician is considered the gold standard, however where expert help may not be easily available, screening tools for NP can be used. The painDETECT questionnaire (PD-Q) is a simple screening tool and has been widely used in several languages. We developed an Arabic version of PD-Q and tested its validity and reliability.

METHODS

The original PD-Q was translated into the Arabic language by a team of experts. The translated version of the PD-Q was administered to the study population, which included patients having moderate to severe pain for at least three months. Reliability of the Arabic version was evaluated by an intra-class-correlation coefficient (ICC) between pre- and post-measures and Cronbach's α values. Validity was measured by receiver operating characteristic (ROC) curve. Expert pain physician diagnosis was considered as the gold standard for comparing the diagnostic accuracy.

RESULTS

A total of 375 patients were included in the study, of which 153 (40.8%) patients were diagnosed with NP and 222 [59.2%] patients had nociceptive pain. The ICC between pre- and post-PD-Q scale total scores for the overall sample, NP group, and NocP group was 0.970 (95% CI, 0.964-0.976), 0.963 (95% CI, 0.949-0.973), and 0.962 (95% CI, 0.951-0.971), respectively. The Cronbach's α values for the post-assessment measures in the overall sample, NP group, and nociceptive pain group, were 0.764, 0.684, and 0.746, respectively. The area under the ROC curve was 0.775 (95% CI, 0.725-0.825) for the PD-Q total score.

CONCLUSION

The Arabic version of the PD-Q showed good reliability and validity in the detection of NP component in patients with chronic pain.

摘要

简介

神经性疼痛(NP)会造成严重的痛苦,因此必须迅速进行诊断和治疗。NP 的诊断可能较为困难,如果由专家疼痛医师进行诊断,则被认为是金标准,然而,在专家帮助可能不易获得的情况下,可以使用 NP 的筛查工具。疼痛 DETECT 问卷(PD-Q)是一种简单的筛查工具,已在多种语言中广泛使用。我们开发了 PD-Q 的阿拉伯语版本,并对其有效性和可靠性进行了测试。

方法

一个专家小组将原始 PD-Q 翻译成阿拉伯语。将翻译后的 PD-Q 版本应用于研究人群,这些人群的疼痛持续时间至少为三个月。使用预测量和后测量之间的组内相关系数(ICC)和 Cronbach's α 值评估阿拉伯语版本的可靠性。通过接收者操作特征(ROC)曲线测量有效性。专家疼痛医师的诊断被认为是比较诊断准确性的金标准。

结果

共有 375 名患者纳入研究,其中 153 名(40.8%)患者被诊断为 NP,222 名(59.2%)患者患有伤害感受性疼痛。总体样本、NP 组和非 NP 组的 PD-Q 量表总分的预测量和后测量之间的 ICC 分别为 0.970(95%CI,0.964-0.976)、0.963(95%CI,0.949-0.973)和 0.962(95%CI,0.951-0.971)。总体样本、NP 组和伤害感受性疼痛组后测量的 Cronbach's α 值分别为 0.764、0.684 和 0.746。PD-Q 总分的 ROC 曲线下面积为 0.775(95%CI,0.725-0.825)。

结论

PD-Q 的阿拉伯语版本在检测慢性疼痛患者的 NP 成分方面表现出良好的可靠性和有效性。