Suppr超能文献

使用可穿戴和移动技术捕捉精神分裂症患者的静息-活动模式:一个远程监测平台的开发、实施、可行性和可接受性

Capturing Rest-Activity Profiles in Schizophrenia Using Wearable and Mobile Technologies: Development, Implementation, Feasibility, and Acceptability of a Remote Monitoring Platform.

作者信息

Meyer Nicholas, Kerz Maximilian, Folarin Amos, Joyce Dan W, Jackson Richard, Karr Chris, Dobson Richard, MacCabe James

机构信息

Department of Psychosis Studies, Institute of Psychiatry, Psychology and Neuroscience, King's College London, London, United Kingdom.

South London and Maudsley National Health Service Foundation Trust, Bethlem Royal Hospital, Beckenham, Kent, United Kingdom.

出版信息

JMIR Mhealth Uhealth. 2018 Oct 30;6(10):e188. doi: 10.2196/mhealth.8292.

Abstract

BACKGROUND

There is growing interest in the potential for wearable and mobile devices to deliver clinically relevant information in real-world contexts. However, there is limited information on their acceptability and barriers to long-term use in people living with psychosis.

OBJECTIVE

This study aimed to describe the development, implementation, feasibility, acceptability, and user experiences of the Sleepsight platform, which harnesses consumer wearable devices and smartphones for the passive and unobtrusive capture of sleep and rest-activity profiles in people with schizophrenia living in their homes.

METHODS

A total of 15 outpatients with a diagnosis of schizophrenia used a consumer wrist-worn device and smartphone to continuously and remotely gather rest-activity profiles over 2 months. Once-daily sleep and self-rated symptom diaries were also collected via a smartphone app. Adherence with the devices and smartphone app, end-of-study user experiences, and agreement between subjective and objective sleep measures were analyzed. Thresholds for acceptability were set at a wear time or diary response rate of 70% or greater.

RESULTS

Overall, 14 out of 15 participants completed the study. In individuals with a mild to moderate symptom severity at baseline (mean total Positive and Negative Syndrome Scale score 58.4 [SD 14.4]), we demonstrated high rates of engagement with the wearable device (all participants meeting acceptability criteria), sleep diary, and symptom diary (93% and 86% meeting criteria, respectively), with negative symptoms being associated with lower diary completion rate. The end-of-study usability and acceptability questionnaire and qualitative analysis identified facilitators and barriers to long-term use, and paranoia with study devices was not a significant barrier to engagement. Comparison between sleep diary and wearable estimated sleep times showed good correspondence (ρ=0.50, P<.001).

CONCLUSIONS

Extended use of wearable and mobile technologies are acceptable to people with schizophrenia living in a community setting. In the future, these technologies may allow predictive, objective markers of clinical status, including early markers of impending relapse.

摘要

背景

可穿戴设备和移动设备在现实环境中提供临床相关信息的潜力正引发越来越多的关注。然而,关于它们在精神病患者中的可接受性以及长期使用的障碍的信息有限。

目的

本研究旨在描述Sleepsight平台的开发、实施、可行性、可接受性和用户体验,该平台利用消费级可穿戴设备和智能手机,对居家的精神分裂症患者的睡眠和休息 - 活动情况进行被动且不引人注意的记录。

方法

总共15名诊断为精神分裂症的门诊患者使用消费级腕戴设备和智能手机,在2个月内持续远程收集休息 - 活动情况。还通过智能手机应用程序收集每日一次的睡眠和自评症状日记。分析了对设备和智能手机应用程序的依从性、研究结束时的用户体验以及主观和客观睡眠测量之间的一致性。可接受性阈值设定为佩戴时间或日记回复率达到70%或更高。

结果

总体而言,15名参与者中有14名完成了研究。在基线时症状严重程度为轻度至中度的个体中(阳性和阴性症状量表总分平均为58.4 [标准差14.4]),我们发现对可穿戴设备(所有参与者均符合可接受性标准)、睡眠日记和症状日记的参与率很高(分别为93%和86%符合标准),阴性症状与日记完成率较低相关。研究结束时的可用性和可接受性问卷以及定性分析确定了长期使用的促进因素和障碍,对研究设备的偏执并非参与的重大障碍。睡眠日记与可穿戴设备估计的睡眠时间之间的比较显示出良好的一致性(ρ = 0.50,P <.001)。

结论

对于居住在社区环境中的精神分裂症患者来说,长期使用可穿戴和移动技术是可以接受的。未来,这些技术可能会提供临床状态的预测性、客观指标,包括即将复发的早期指标。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/4048/6234334/e69b301317b9/mhealth_v6i10e188_fig1.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验