Suppr超能文献

非镇静婴儿获取可用磁共振成像的非药物策略:系统评价和荟萃分析。

Non-pharmacological strategies to obtain usable magnetic resonance images in non-sedated infants: Systematic review and meta-analysis.

机构信息

School of Nursing, University of Mississippi Medical Center, 2500 North State Street, Jackson 39216, MS, United States.

Burrell College of Osteopathic Medicine, 3501 Arrowhead Dr Las Cruces, NM 88001, United States.

出版信息

Int J Nurs Stud. 2020 Jun;106:103551. doi: 10.1016/j.ijnurstu.2020.103551. Epub 2020 Feb 22.

Abstract

BACKGROUND

Although the use of sedation is commonly practiced to keep infants still while receiving magnetic resonance imaging, non-pharmacological strategies are a potential alternative.

OBJECTIVES

The purpose of this study was to determine the success rate of obtaining usable magnetic resonance images in infants with the sole use of non-pharmacological strategies.

DESIGN

Systematic literature review and meta-analysis SETTING: A search was conducted in PubMed, CINAHL and Cochrane Library.

PARTICIPANTS

Human infants from birth to 24 months of age who did not receive any sedation or anesthesia during magnetic resonance imaging METHOD: Articles that reported the success rate of obtaining usable images were included.

RESULTS

Of the 521 non-duplicate articles found, 58 articles were included in the systematic review with sample sizes ranging from 2-457, an average success rate of 87.8%, and an average scan time of 30 min. The most common non-pharmacological technique included feeding and swaddling infants before imaging to encourage infants to sleep during the scan. Meta-analysis performed on 53 articles comprising 3,410 infants found a success rate of 87%, but significant heterogeneity was found (I = 98.30%). It was more difficult to obtain usable images solely with non-pharmacological techniques if infants were critically ill or a structural magnetic resonance imaging of the brain was required.

CONCLUSION

Non-pharmacological techniques are effective for obtaining usable magnetic resonance imaging scans in most but not all infants. Tweetable abstract: Non-pharmacological techniques are effective for obtaining usable magnetic resonance imaging scans in most infants.

摘要

背景

尽管在进行磁共振成像检查时,常使用镇静剂使婴儿保持静止,但非药物策略也是一种潜在的替代方法。

目的

本研究旨在确定仅使用非药物策略获得可使用磁共振图像的成功率。

设计

系统文献回顾和荟萃分析

设置

在 PubMed、CINAHL 和 Cochrane Library 中进行检索。

参与者

在磁共振成像检查期间未接受任何镇静或麻醉的出生至 24 个月龄的婴儿。

方法

纳入报告获得可使用图像成功率的文章。

结果

在 521 篇非重复文章中,有 58 篇文章纳入系统综述,样本量范围为 2-457 例,平均成功率为 87.8%,平均扫描时间为 30 分钟。最常见的非药物技术包括在成像前给婴儿喂食和包裹,以鼓励婴儿在扫描过程中入睡。对包含 3410 例婴儿的 53 篇文章进行荟萃分析发现成功率为 87%,但存在显著异质性(I = 98.30%)。如果婴儿病重或需要进行脑部结构磁共振成像,则仅使用非药物技术更难获得可使用的图像。

结论

非药物技术在大多数但并非所有婴儿中均有效获得可使用的磁共振成像扫描。

相似文献

1
Non-pharmacological strategies to obtain usable magnetic resonance images in non-sedated infants: Systematic review and meta-analysis.
Int J Nurs Stud. 2020 Jun;106:103551. doi: 10.1016/j.ijnurstu.2020.103551. Epub 2020 Feb 22.
2
Can we reduce anesthesia exposure? Neonatal brain MRI: Swaddling vs. sedation, a national survey.
J Clin Anesth. 2017 May;38:119-122. doi: 10.1016/j.jclinane.2017.01.034. Epub 2017 Feb 8.
3
Experience with a "Feed and Swaddle" program in infants up to six months of age.
Acta Anaesthesiol Scand. 2020 Jan;64(1):63-68. doi: 10.1111/aas.13471. Epub 2019 Oct 7.
6
Techniques for minimizing sedation in pediatric MRI.
J Magn Reson Imaging. 2019 Oct;50(4):1047-1054. doi: 10.1002/jmri.26703. Epub 2019 Mar 14.
7
Feed and Wrap MRI Technique in Infants.
Clin Pediatr (Phila). 2017 Oct;56(12):1095-1103. doi: 10.1177/0009922816677806. Epub 2016 Nov 23.
8
Sevoflurane sedation in infants undergoing MRI: a preliminary report.
Paediatr Anaesth. 2005 Jan;15(1):16-22. doi: 10.1111/j.1460-9592.2005.01456.x.
9
Feasibility of cerebral MRI in non-sedated preterm-born infants at term-equivalent age: report of a single centre.
Acta Paediatr. 2011 Dec;100(12):1544-7. doi: 10.1111/j.1651-2227.2011.02388.x. Epub 2011 Jul 8.

引用本文的文献

1
Practical strategies to improve MRI operations and workflow in pediatric radiology.
Pediatr Radiol. 2025 Jan;55(1):12-23. doi: 10.1007/s00247-024-06114-0. Epub 2024 Dec 20.
2
Optimizing infant neuroimaging methods to understand the neurodevelopmental impacts of early nutrition and feeding.
Dev Cogn Neurosci. 2025 Jan;71:101481. doi: 10.1016/j.dcn.2024.101481. Epub 2024 Nov 23.
3
Sedation and anesthesia for imaging of the infant and neonate-a brief review.
Pediatr Radiol. 2024 Sep;54(10):1579-1588. doi: 10.1007/s00247-024-05995-5. Epub 2024 Jul 26.
4
White matter microstructure predicts individual differences in infant fear (But not anger and sadness).
Dev Sci. 2023 May;26(3):e13340. doi: 10.1111/desc.13340. Epub 2022 Nov 20.
5
Real-time motion monitoring improves functional MRI data quality in infants.
Dev Cogn Neurosci. 2022 Jun;55:101116. doi: 10.1016/j.dcn.2022.101116. Epub 2022 May 21.
6
Paediatric brain MRI findings following congenital heart surgery: a systematic review.
Arch Dis Child. 2022 Sep;107(9):818-825. doi: 10.1136/archdischild-2021-323132. Epub 2022 Mar 22.

本文引用的文献

1
Techniques for minimizing sedation in pediatric MRI.
J Magn Reson Imaging. 2019 Oct;50(4):1047-1054. doi: 10.1002/jmri.26703. Epub 2019 Mar 14.
2
Functional magnetic resonance urography in infants: feasibility of a feed-and-sleep technique.
Pediatr Radiol. 2019 Mar;49(3):351-357. doi: 10.1007/s00247-018-4307-5. Epub 2018 Nov 26.
3
Fast, free-breathing and motion-minimized techniques for pediatric body magnetic resonance imaging.
Pediatr Radiol. 2018 Aug;48(9):1197-1208. doi: 10.1007/s00247-018-4116-x. Epub 2018 Aug 4.
4
Fast and accurate Slicewise OutLIer Detection (SOLID) with informed model estimation for diffusion MRI data.
Neuroimage. 2018 Nov 1;181:331-346. doi: 10.1016/j.neuroimage.2018.07.003. Epub 2018 Jul 5.
5
The development of brain white matter microstructure.
Neuroimage. 2018 Nov 15;182:207-218. doi: 10.1016/j.neuroimage.2017.12.097. Epub 2018 Jan 3.
6
Mapping White Matter Microstructure in the One Month Human Brain.
Sci Rep. 2017 Aug 29;7(1):9759. doi: 10.1038/s41598-017-09915-6.
8
Quantification of neonatal lung parenchymal density via ultrashort echo time MRI with comparison to CT.
J Magn Reson Imaging. 2017 Oct;46(4):992-1000. doi: 10.1002/jmri.25643. Epub 2017 Feb 3.
9
Strategies to minimize sedation in pediatric body magnetic resonance imaging.
Pediatr Radiol. 2016 May;46(6):916-27. doi: 10.1007/s00247-016-3613-z. Epub 2016 May 26.
10
Comparison of non-sedated brain MRI and CT for the detection of acute traumatic injury in children 6 years of age or less.
Emerg Radiol. 2016 Aug;23(4):325-31. doi: 10.1007/s10140-016-1392-3. Epub 2016 May 11.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验