消毒湿巾的交叉污染因产品化学性质和菌株而异。

Cross-contamination by disinfectant towelettes varies by product chemistry and strain.

机构信息

Department of Food Science, Purdue University, 745 Agriculture Mall Drive, West Lafayette, IN, 47907, USA.

Diversey Inc., Charlotte, NC, 28273, USA.

出版信息

Antimicrob Resist Infect Control. 2020 Aug 24;9(1):141. doi: 10.1186/s13756-020-00797-4.

Abstract

BACKGROUND

Disinfectant products are used frequently on environmental surfaces (e.g. medical equipment, countertops, patient beds) and patient care equipment within healthcare facilities. The purpose of this study was to assess the risk of cross-contamination of Staphylococcus aureus and Pseudomonas aeruginosa during and after disinfection of predetermined surface areas with ready-to-use (RTU) pre-wetted disinfectant towelettes.

METHODS

This study tested six disinfectant towelette products against S. aureus ATCC CRM-6538 and P. aeruginosa strain ATCC-15442 on Formica surfaces. Each disinfectant was evaluated on a hard nonporous surface and efficacy was measured every 0.5 m using a modified version of EPA MLB SOP-MB-33 to study the risk of cross-contamination.

RESULTS

We found that all of the wipes used in this study transferred S. aureus and P. aeruginosa from an inoculated surface to previously uncontaminated surfaces. Disinfectant towelettes with certain chemistries also retained a high level of viable bacteria after disinfection of the surface area. The cross-contamination risk also varied by product chemistry and bacterial strain.

CONCLUSION

Disinfectant wipes can cross-contaminate hard nonporous surfaces and retain viable bacterial cells post-disinfection, especially over larger surface areas. This highlights a need to further investigate the risk disinfectant wipes pose during and post-disinfection and guidance on maximum surface areas treated with a single towelette.

摘要

背景

在医疗机构内,消毒剂产品经常用于环境表面(例如医疗设备、台面、患者病床)和患者护理设备。本研究的目的是评估使用即用型(RTU)预湿消毒剂擦拭巾对预定表面进行消毒和消毒后,金黄色葡萄球菌和铜绿假单胞菌交叉污染的风险。

方法

本研究在富美家(Formica)表面上使用 6 种消毒剂擦拭巾对金黄色葡萄球菌 ATCC CRM-6538 和铜绿假单胞菌 ATCC-15442 进行了测试。每种消毒剂均在坚硬的非多孔表面上进行了评估,并使用 EPA MLB SOP-MB-33 的修改版每 0.5 m 测量一次功效,以研究交叉污染的风险。

结果

我们发现,本研究中使用的所有擦拭巾都将金黄色葡萄球菌和铜绿假单胞菌从接种表面转移到了先前未受污染的表面。具有某些化学特性的消毒剂擦拭巾在对表面区域进行消毒后,也保留了大量存活的细菌。交叉污染的风险还因产品化学特性和细菌菌株而异。

结论

消毒剂擦拭巾会对坚硬的非多孔表面造成交叉污染,并在消毒后保留存活的细菌细胞,尤其是在较大的表面区域上。这突出表明需要进一步研究消毒剂擦拭巾在消毒过程中和消毒后带来的风险,以及有关使用单个擦拭巾处理的最大表面区域的指南。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/a5e6/7446058/aa487be6aeee/13756_2020_797_Fig1_HTML.jpg