Associations between ventilation and children's asthma and allergy in naturally ventilated Chinese homes.

机构信息

Tianjin Key Lab. of Indoor Air Environmental Quality Control, School of Environmental Science and Engineering, Tianjin University, Tianjin, China.

出版信息

Indoor Air. 2021 Mar;31(2):383-391. doi: 10.1111/ina.12742. Epub 2020 Sep 28.

Abstract

Building ventilation is important for occupants' health. There are few studies of associations between home ventilation and occupant's health in China. During 2013-2016, we measured ventilation in 399 homes in Tianjin and Cangzhou, China, and surveyed the health history of children. Ventilation rates were measured using mass balance of occupant generated CO . The associations of home ventilation with children's asthma and allergy were analyzed in different strata of time and space. A low bedroom ventilation at night was significantly associated with an increased proportion of rhinitis among children (rhinitis current, adjusted odds ratio (AOR): 1.59; 95% confidence interval (CI): 1.01-2.49; diagnosed rhinitis, AOR: 3.02 (1.16-7.89)). Our findings suggest a dose-response relationship between ventilation rate at night in children's bedrooms and rhinitis current. The night-time ventilation rate in bedrooms has a greater association with rhinitis than the whole home ventilation rate during daytime.

摘要

建筑通风对于居住者的健康很重要。在中国,关于家庭通风与居住者健康之间关联的研究很少。在 2013 年至 2016 年期间,我们在中国天津和沧州的 399 户家庭中测量了通风情况,并调查了儿童的健康史。使用人员产生的 CO 的质量平衡来测量通风率。我们分析了家庭通风与儿童哮喘和过敏在不同时间和空间层的关联。夜间卧室低通风率与儿童鼻炎的比例增加显著相关(鼻炎当前,调整后的优势比(AOR):1.59;95%置信区间(CI):1.01-2.49;确诊鼻炎,AOR:3.02(1.16-7.89))。我们的研究结果表明,儿童卧室夜间通风率与鼻炎当前之间存在剂量反应关系。与日间整个家庭的通风率相比,夜间卧室的通风率与鼻炎的相关性更大。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验