Department of Infectious Diseases, Chonnam National University Medical School, Gwangju, Korea.
Department of Laboratory Medicine, Chonnam National University Medical School, Gwangju, Korea.
J Korean Med Sci. 2020 Sep 21;35(37):e332. doi: 10.3346/jkms.2020.35.e332.
The purpose of this study was to determine the extent of air and surface contamination of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) in four health care facilities with hospitalized coronavirus disease 2019 (COVID-19) patients.
We investigated air and environmental contamination in the rooms of eight COVID-19 patients in four hospitals. Some patients were in negative-pressure rooms, and others were not. None had undergone aerosol-generating procedures. On days 0, 3, 5, and 7 of hospitalization, the surfaces in the rooms and anterooms were swabbed, and air samples were collected 2 m from the patient and from the anterooms.
All 52 air samples were negative for SARS-CoV-2 RNA. Widespread surface contamination of SARS-CoV-2 RNA was observed. In total, 89 of 320 (27%) environmental surface samples were positive for SARS-CoV-2 RNA. Surface contamination of SARS-CoV-2 RNA was common in rooms without surface disinfection and in rooms sprayed with disinfectant twice a day. However, SARS-CoV-2 RNA was not detected in a room cleaned with disinfectant wipes on a regular basis.
Our data suggest that remote (> 2 m) airborne transmission of SARS-CoV-2 from hospitalized COVID-19 patients is uncommon when aerosol-generating procedures have not been performed. Surface contamination was widespread, except in a room routinely cleaned with disinfectant wipes.
本研究旨在确定在四家有住院 COVID-19 患者的医疗机构中,严重急性呼吸综合征冠状病毒 2(SARS-CoV-2)的空气和表面污染程度。
我们调查了四家医院的 8 名 COVID-19 患者病房内的空气和环境污染情况。一些患者处于负压病房,而另一些则不是。患者均未进行产生气溶胶的操作。在住院的第 0、3、5 和 7 天,对房间和前室的表面进行拭子取样,并采集距离患者 2 米和前室的空气样本。
所有 52 个空气样本均未检测到 SARS-CoV-2 RNA。广泛存在 SARS-CoV-2 RNA 的表面污染。共有 320 个环境表面样本中的 89 个(27%)为 SARS-CoV-2 RNA 阳性。未进行表面消毒的房间和每天喷洒消毒剂两次的房间中,SARS-CoV-2 RNA 的表面污染很常见。然而,在定期使用消毒剂擦拭的房间中未检测到 SARS-CoV-2 RNA。
我们的数据表明,在未进行产生气溶胶的操作时,来自住院 COVID-19 患者的 SARS-CoV-2 远程(> 2 m)空气传播并不常见。除了定期用消毒剂擦拭的房间外,表面污染非常普遍。