Asena Leyla, Kırcı Dogan İrem, Oto Sibel, Dursun Altınors Dilek
From the Department of Ophthalmology, Baskent University Faculty of Medicine, Ankara, Turkey.
J Cataract Refract Surg. 2023 May 1;49(5):504-511. doi: 10.1097/j.jcrs.0000000000001142.
To compare visual performance and quality of life (QoL) following bilateral implantation of a new nondiffractive extended depth-of-focus (EDOF) intraocular lens (IOL) and a trifocal IOL.
Department of Ophthalmology, Baskent University Faculty of Medicine, Ankara, Turkey.
Prospective comparative interventional case series.
104 eyes of 52 patients with cataract, bilaterally implanted with a nondiffractive EDOF IOL or a trifocal IOL, were included. Outcome measures were uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), distance corrected intermediate visual acuity and distance corrected near visual acuity, defocus curves, QoL (Visual Function Index 14), quality of vision (Quality of Vision [QoV] index), contrast sensitivity (Pelli-Robson chart), and binocular reading speed.
Twenty-six patients were included in each group. The UDVA and CDVA were better in the EDOF group (0.05 ± 0.04 and 0.01 ± 0.04) than the trifocal group (0.13 ± 0.06 and 0.11 ± 0.07) ( P = .02 and .01). Defocus curves showed that visual acuity was better with the EDOF IOL for vergences at 0.00, -0.50, and -1.00 and better with the trifocal IOL for vergences at -2.50, -3.00, -3.50, and -4.00. Contrast sensitivity scores were similar with both IOLs ( P = .12). The overall mean QoL scores were lower in the EDOF group, indicating a better QoL ( P = .04). The QoV was better in the EDOF group with significantly less glare, halos, and blurry vision ( P < .01).
The EDOF IOL performed better at distance, and the trifocal IOL performed better at near. Overall QoL and quality of vision were better with the EDOF IOL.
比较新型非衍射性扩展焦深(EDOF)人工晶状体(IOL)和三焦点IOL双眼植入后的视觉性能和生活质量(QoL)。
土耳其安卡拉巴斯肯大学医学院眼科。
前瞻性比较干预性病例系列。
纳入52例白内障患者的104只眼,双眼植入非衍射性EDOF IOL或三焦点IOL。观察指标包括未矫正远视力(UDVA)、矫正远视力(CDVA)、远矫正中视力和远矫正近视力、散焦曲线、QoL(视觉功能指数14)、视觉质量(视觉质量[QoV]指数)、对比敏感度(贝利-罗布森图表)和双眼阅读速度。
每组纳入26例患者。EDOF组的UDVA和CDVA(分别为0.05±0.04和0.01±0.04)优于三焦点组(分别为0.13±0.06和0.11±0.07)(P = 0.02和0.01)。散焦曲线显示,对于0.00、-0.50和-1.00的聚散度,EDOF IOL的视力更好;对于-2.50、-3.00、-3.50和-4.00的聚散度,三焦点IOL的视力更好。两种IOL的对比敏感度评分相似(P = 0.12)。EDOF组的总体平均QoL评分较低,表明QoL更好(P = 0.04)。EDOF组的QoV更好,眩光、光晕和视物模糊明显更少(P < 0.01)。
EDOF IOL在远视力方面表现更好,三焦点IOL在近视力方面表现更好。EDOF IOL的总体QoL和视觉质量更好。