INTRODUCTION

A newly developed diffractive continuous range of vision (CRV) intraocular lens (IOL) (TECNIS Odyssey) was introduced to reduce photic phenomena compared to the previous model (Synergy). This brief report is the first to evaluate the early postoperative outcomes of the new CRV IOL in a Japanese population.

METHODS

This retrospective review included 50 eyes of 25 patients with cataracts who underwent bilateral implantation of modified CRV IOLs (models DNR00V and DRT150-375, TECNIS Odyssey). Clinical records of the patients were obtained. One month postoperative assessments included monocular and binocular uncorrected visual acuity (UCVA) and distance-corrected visual acuity (DCVA) at 5 m, 60 cm, and 40 cm. Additionally, binocular photopic contrast sensitivity, defocus curve, spectacle independence, incidence of photic phenomena, and overall patient satisfaction were evaluated.

RESULTS

The mean patient age was 65.2 ± 8.4 years, with a mean IOL power of 17.4 ± 4.7 D. Postoperative binocular UCVA/DCVA (logMAR) at 5 m, 60 cm, and 40 cm was - 0.18 ± 0.06/ - 0.21 ± 0.06, - 0.01 ± 0.08/ - 0.01 ± 0.08, and 0.00 ± 0.08/0.00 ± 0.07, respectively. Contrast sensitivity remained within normal limits at all spatial frequencies. The binocular defocus curve showed DCVA of 0.0 logMAR or better across a range from + 0.5 to - 2.0 D. Spectacle independence was achieved in 64% of patients, whereas the remainder required reading glasses. Reports of glare and starburst were minimal (84% and 76% of patients reported none or minimal, respectively), whereas 52% experienced moderate to severe halos. Overall, 96% of the patients were satisfied or very satisfied with their distance and intermediate vision, and 68% were satisfied with their near vision.

CONCLUSIONS

The new diffractive CRV IOL offers simultaneous vision across a broad range, with improved tolerance to photic phenomena, while maintaining comparable visual acuity at far, intermediate, and near distances compared to the previous model.

摘要

引言

一种新开发的衍射连续视程(CRV)人工晶状体(IOL)(TECNIS Odyssey)被引入,以减少与先前型号(Synergy)相比的光学现象。本简要报告首次评估了这种新型CRV IOL在日本人群中的早期术后效果。

方法

这项回顾性研究纳入了25例白内障患者的50只眼,这些患者接受了改良CRV IOL(型号DNR00V和DRT150 - 375,TECNIS Odyssey)的双侧植入。获取了患者的临床记录。术后1个月的评估包括单眼和双眼未矫正视力(UCVA)以及在5米、60厘米和40厘米处的距离矫正视力(DCVA)。此外,还评估了双眼明视对比敏感度、散焦曲线、眼镜独立性、光学现象的发生率以及患者的总体满意度。

结果

患者的平均年龄为65.2±8.4岁,人工晶状体的平均屈光度为17.4±4.7 D。术后在5米、60厘米和40厘米处的双眼UCVA/DCVA(logMAR)分别为 - 0.18±0.06 / - 0.21±0.06、 - 0.01±0.08 / - 0.01±0.08和0.00±0.08 / 0.00±0.07。在所有空间频率下,对比敏感度均保持在正常范围内。双眼散焦曲线显示,在 + 0.5至 - 2.0 D的范围内,DCVA为0.0 logMAR或更好。64%的患者实现了无眼镜独立,而其余患者需要阅读眼镜。眩光和星芒现象的报告很少(分别有84%和76%的患者报告无或极少);然而,52%的患者经历了中度至重度的光晕。总体而言,96%的患者对其远视力和中距离视力感到满意或非常满意,68%的患者对其近视力感到满意。

结论

新型衍射CRV IOL在广泛范围内提供同时视,对光学现象的耐受性有所提高,同时与先前型号相比,在远、中、近距离保持了相当的视力。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验