Abstract

OBJECTIVES

Droplets or aerosols loaded with SARS-CoV-2 can be released during breathing, coughing, or sneezing from COVID-19-infected persons. To investigate whether the most commonly applied air-cleaning device in dental clinics, the oral spray suction machine (OSSM), can provide protection to healthcare providers working in clinics against exposure to bioaerosols during dental treatment.

METHOD

In this study, we measured and characterized the temporal and spatial variations in bioaerosol concentration and deposition with and without the use of the OSSM using an experimental design in a dental clinic setting. Serratia marcescens (a bacterium) and ΦX174 phage (a virus) were used as tracers. The air sampling points were sampled using an Anderson six-stage sampler, and the surface-deposition sampling points were sampled using the natural sedimentation method. The Computational Fluid Dynamics method was adopted to simulate and visualize the effect of the OSSM on the concentration spatial distribution.

RESULTS

During dental treatment, the peak exposure concentration increased by up to 2-3 orders of magnitude (PFU/m) for healthcare workers. Meanwhile, OSSM could lower the mean bioaerosol exposure concentration from 58.84 PFU/m to 4.10 PFU/m for a healthcare worker, thereby inhibiting droplet and airborne transmission. In terms of deposition, OSSM significantly reduced the bioaerosol surface concentration from 28.1 PFU/m to 2.5 PFU/m for a surface, effectively preventing fomite transmission.

CONCLUSION

The use of OSSM showed the potential to restraint the spread of bioaerosols in clinical settings. Our study demonstrates that OSSM use in dental clinics can reduce the exposure concentrations of bioaerosols for healthcare workers during dental treatment and is beneficial for minimizing the risk of infectious diseases such as COVID-19.

摘要

目的

新冠病毒感染者在呼吸、咳嗽或打喷嚏时会释放携带 SARS-CoV-2 的飞沫或气溶胶。本研究旨在调查口腔喷雾抽吸机(OSSM)这种牙科诊所最常使用的空气净化设备,是否可以为诊所内的医护人员在进行牙科治疗时免受生物气溶胶暴露提供保护。

方法

本研究采用实验设计,在牙科诊所环境中,测量和描述了使用和不使用 OSSM 时生物气溶胶浓度和沉积的时空变化。使用粘质沙雷氏菌(一种细菌)和 ΦX174 噬菌体(一种病毒)作为示踪剂。空气采样点使用安德森六级采样器进行采样,表面沉积采样点使用自然沉降法进行采样。采用计算流体动力学方法模拟和可视化 OSSM 对浓度空间分布的影响。

结果

在牙科治疗过程中,医护人员的峰值暴露浓度最高可达 2-3 个数量级(PFU/m)。同时,OSSM 可将医护人员的平均生物气溶胶暴露浓度从 58.84 PFU/m 降低至 4.10 PFU/m,从而抑制飞沫和气溶胶传播。在沉积方面,OSSM 可显著降低表面的生物气溶胶浓度,从 28.1 PFU/m 降低至 2.5 PFU/m,有效防止接触传播。

结论

OSSM 的使用显示出在临床环境中抑制生物气溶胶传播的潜力。本研究表明,牙科诊所使用 OSSM 可以降低医护人员在牙科治疗过程中的生物气溶胶暴露浓度,有助于最大限度地降低 COVID-19 等传染病的风险。