Li Hongqi, Yan Jiabao, Jiang Lin, Zhao Yong, Song Yanxi, Yu Jirui, Cheng Lang
College of Chemistry and Chemical Engineering, Donghua University, Shanghai, 201620, China.
School of Chemistry and Material Engineering, Huainan Normal University, Huainan, 232038, Anhui Province, China.
J Fluoresc. 2024 Nov;34(6):2793-2806. doi: 10.1007/s10895-023-03478-8. Epub 2023 Nov 3.
Development of fluorescent sensors with large Stokes shift for selective detection of heavy metals is of great importance. A novel fluorescent probe with extremely large Stokes shift (212 nm) was synthesized for selective and simultaneous detection of Hg and Ag ions. The deep yellow probe turned colorless or pale yellow after addition of Hg or Ag. The new probe could be utilized for absorption spectral detection of Hg and Ag both in ethanol and aqueous solution. Addition of Hg and Ag ions caused significant decrease in the fluorescence intensity of the new probe and the selective recognition of Hg and Ag was not interfered by common competitive metal ions including Li, Na, K, Cu, Fe, Zn, Co, Ni, Mn, Sr, Ca, Mg, Al, Cr and Fe. The detection limit for Hg and Ag was calculated to be 4.68 μM and 4.29 μM, respectively. Application of the new probe for quantitative determination of Hg and Ag concentrations in real water samples was accomplished.
开发具有大斯托克斯位移的荧光传感器用于选择性检测重金属具有重要意义。合成了一种具有极大斯托克斯位移(212 nm)的新型荧光探针,用于选择性同时检测汞离子和银离子。加入汞或银后,深黄色探针变为无色或浅黄色。这种新型探针可用于乙醇和水溶液中汞和银的吸收光谱检测。加入汞离子和银离子会导致新型探针的荧光强度显著降低,并且汞和银的选择性识别不受包括锂、钠、钾、铜、铁、锌、钴、镍、锰、锶、钙、镁、铝、铬和铁在内的常见竞争性金属离子的干扰。计算得出汞和银的检测限分别为4.68 μM和4.29 μM。实现了新型探针在实际水样中汞和银浓度定量测定的应用。