Miao Caiqin, Wang Qun, Yang Shuang, Tang Yihui, Liu Xiyan, Lu Songtao
School of Chemistry and Chemical Engineering, Harbin Institute of Technology, Harbin, 150001, China.
School of Chemistry and Chemical Engineering, Harbin Institute of Technology, Harbin, 150001, China.
Talanta. 2024 Aug 1;275:126070. doi: 10.1016/j.talanta.2024.126070. Epub 2024 Apr 24.
Exploration effective route to convert plastic waste into valuable carbon dots with bifunction of metal fluorescence monitoring and corrosion protection in seawater is promising. Herein, using "white-pollution" polypropylene surgical masks as a single precursor, dual-emitting carbon dots (CDs) with excellent ratiometric fluorescent sensitivity and corrosion inhibitor efficiency were fabricated with high yield (∼100 %) by a one-pot in situ acid oxidation hydrothermal strategy without post-treatment and organic solvents. Chemical, structural, morphological, optical properties and the Cr (VI) detection and Cu inhibition mechanism of the synthesized CDs had been systematically studied. Furthermore, a dual-response-OFF proportional fluorescent probe had been developed for the detection of the analyte Cr (VI) with a low detection limit of 24 nM. Additionally, the corrosion inhibition efficiency of the prepared CDs reached approximately 94.01 % for Cu substrate in 3.5 wt% NaCl electrolyte under a CDs concentration of 200 mg/L, which is higher than that of most previous reports.
探索将塑料垃圾转化为具有金属荧光监测和海水腐蚀防护双功能的有价值碳点的有效途径很有前景。在此,以“白色污染”的聚丙烯外科口罩作为单一前驱体,通过一锅原位酸氧化水热策略,无需后处理和有机溶剂,以高产率(约100%)制备了具有优异比率荧光灵敏度和缓蚀效率的双发射碳点。对合成的碳点的化学、结构、形态、光学性质以及Cr(VI)检测和Cu抑制机制进行了系统研究。此外,还开发了一种双响应-OFF比例荧光探针用于检测分析物Cr(VI),检测限低至24 nM。此外,在200 mg/L的碳点浓度下,制备的碳点在3.5 wt% NaCl电解液中对Cu基体的缓蚀效率达到约94.01%,高于大多数先前报道。