PURPOSE

Hydrophilicity is gaining increasing interest as a factor that might influence the osseointegration of dental implants. Therefore, in this study the dynamic wetting behavior of currently marketed dental titanium implants was analyzed by tensiometry, and its relationship to surface topography was examined.

MATERIALS AND METHODS

Nine screw-type implant systems from eight manufacturers were evaluated. Dynamic water contact angles were analyzed by tensiometric multiloop Wilhelmy experiments (10 loops, 10 mm/min immersion speed). The wetted length (perimeter) of the immersed samples was estimated by three-dimensional picture profile measurement of the thread height of the respective implant screws. Wettability was quantified by first advancing contact angles. Additionally, static contact angles were determined using the sessile drop technique. All implant surfaces were characterized by scanning electron microscopy (SEM). Contact angle data were subjected to one-way analysis of variance followed by the Student t test.

RESULTS

SEM revealed different types of surface morphology resulting from the different manufacturing processes. The first advancing mean contact angles of all implants ranged from 0 degrees (SLActive) to 138 degrees (OsseoSpeed), demonstrating statistically significant differences between implants. Because of kinetic hysteresis, initially hydrophobic implants became hydrophilic during following immersion loops.

CONCLUSIONS

The tensiometric method was used to compare wettability of dental implants. A range from fully wettable/superhydrophilic to virtually unwettable/hydrophobic was observed on the implant surfaces examined.

摘要

目的

亲水性作为一种可能影响牙种植体骨整合的因素,其受到越来越多的关注。因此,本研究通过张力法分析了目前市售牙科钛种植体的动态润湿行为,并研究了其与表面形貌的关系。

材料与方法

评估了来自 8 家制造商的 9 种螺钉式种植体系统。通过张力法多环威尔海姆(Wilhelmy)实验(10 个环,浸入速度 10mm/min)分析动态水接触角。通过对各种植体螺钉螺纹高度的三维图像轮廓测量来估计浸入样品的润湿长度(周长)。通过前进接触角来量化润湿性。此外,还使用悬滴技术确定静态接触角。所有种植体表面均采用扫描电子显微镜(SEM)进行表征。接触角数据采用单因素方差分析,然后进行学生 t 检验。

结果

SEM 显示出不同的表面形貌,这是由于不同的制造工艺所致。所有植入物的第一前进平均接触角范围从 0 度(SLActive)到 138 度(OsseoSpeed),表明植入物之间存在统计学差异。由于动力学滞后,最初疏水的植入物在随后的浸入循环中变得亲水。

结论

本研究采用张力法比较了牙种植体的润湿性。在所检查的种植体表面上观察到从完全润湿/超亲水到几乎不润湿/疏水的范围。