Early availability of microbiological results can improve treatment decisions of patients suffering from bloodstream infections. Direct inoculation of automated susceptibility testing (AST) platforms is an approach to shorten time-to-result in blood culture diagnostics. We performed a comparative evaluation of the two commercial AST systems VITEK®-2 and BD Phoenix™ for the direct inoculation with blood culture samples. Furthermore, two different methods of sample preparation were compared in this study. Positive blood cultures were prepared for direct inoculation by use of serum separator tubes and twofold centrifugation. AST was performed with the VITEK®-2 and the BD Phoenix™ system by the standard method according to the manufacturer's recommendations using subcultures on solid media and by direct inoculation of blood culture samples. A hundred clinical samples from blood cultures were included in this study. Rapid AST by direct inoculation showed inter-test agreement rates ranging from 92.45 to 97.7%. Comparing both AST platforms, the VITEK®-2 system demonstrated a higher test accuracy for direct inoculation. No relevant difference was observed for the two different sample preparation methods. Direct inoculation is an easy and inexpensive approach to obtain early full panel phenotypic AST results in blood culture diagnostics. Sample preparation is sufficiently performed by a simple centrifugation method. Both commercial platforms, the VITEK®-2 and the BD Phoenix™, have proven suitable for the use of direct inoculation.

摘要

早期获得微生物学结果可以改善血流感染患者的治疗决策。直接接种自动化药敏检测(AST)平台是缩短血培养诊断结果时间的一种方法。我们对两种商业 AST 系统 VITEK®-2 和 BD Phoenix™ 进行了比较评估,用于直接接种血培养样本。此外,本研究还比较了两种不同的样品制备方法。阳性血培养物通过使用血清分离管和两倍离心法制备用于直接接种。AST 是通过使用固体培养基上的亚培养物和直接接种血培养物样本,根据制造商的建议,使用标准方法在 VITEK®-2 和 BD Phoenix™系统上进行的。本研究纳入了 100 份来自血培养的临床样本。直接接种的快速 AST 显示出 92.45%至 97.7%的测试一致性率。比较两种 AST 平台,VITEK®-2 系统在直接接种时表现出更高的测试准确性。两种不同的样品制备方法之间没有观察到相关差异。直接接种是一种简单且经济的方法,可在血培养诊断中获得早期的全谱表型 AST 结果。样品制备通过简单的离心方法充分完成。VITEK®-2 和 BD Phoenix™ 这两个商业平台都已被证明适合直接接种。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验