Suppr超能文献

一种用于真实、假和多靶点经颅磁刺激的神经刺激器系统。

A neurostimulator system for real, sham, and multi-target transcranial magnetic stimulation.

机构信息

MRC Brain Network Dynamics Unit, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford OX1 3TH, United Kingdom.

Department of Engineering Science, University of Oxford, Oxford OX1 3PJ, United Kingdom.

出版信息

J Neural Eng. 2022 Apr 12;19(2). doi: 10.1088/1741-2552/ac60c9.

Abstract

Transcranial magnetic stimulation (TMS) is a clinically effective therapeutic instrument used to modulate neural activity. Despite three decades of research, two challenging issues remain, the possibility of changing the (a) stimulated spot and (b) stimulation type (real or sham) without physically moving the coil. In this study, a second-generation programmable TMS device with advanced stimulus shaping is introduced that uses a five-level cascaded H-bridge inverter and phase-shifted pulse-width modulation. The principal idea of this research is to obtain real, sham, and multi-locus stimulation using the same TMS system.We propose a two-channel modulation-based magnetic pulse generator and a novel coil arrangement, consisting of two circular coils with a physical distance of 20 mm between the coils and a control method for modifying the effective stimulus intensity, which leads to the live steerability of the target and type of stimulation.Based on the measured system performance, the stimulation profile can be steered ±20 mm along a line from the centroid of the coil locations by modifying the modulation index.The proposed system supports electronic control of the stimulation spot without physical coil movement, resulting in tunable modulation of targets, which is a crucial step towards automated TMS machines.

摘要

经颅磁刺激(TMS)是一种临床有效的治疗工具,用于调节神经活动。尽管已经进行了三十年的研究,但仍存在两个具有挑战性的问题,即无需物理移动线圈就有可能改变(a)刺激点和(b)刺激类型(真实或假刺激)。在这项研究中,引入了一种具有先进刺激成形功能的第二代可编程 TMS 设备,该设备使用五级级联 H 桥逆变器和相移脉冲宽度调制。本研究的主要思想是使用相同的 TMS 系统获得真实、假刺激和多焦点刺激。我们提出了一种基于双通道调制的磁脉冲发生器和一种新颖的线圈布置,由两个具有 20mm 物理距离的圆形线圈组成,并提出了一种用于修改有效刺激强度的控制方法,从而实现了目标和刺激类型的实时可操纵性。基于测量的系统性能,通过修改调制指数,可以将刺激轮廓从线圈位置的质心沿一条线±20mm 进行引导。所提出的系统支持刺激点的电子控制,无需物理线圈移动,从而实现目标的可调谐调制,这是实现自动化 TMS 机器的关键步骤。

相似文献

1
A neurostimulator system for real, sham, and multi-target transcranial magnetic stimulation.
J Neural Eng. 2022 Apr 12;19(2). doi: 10.1088/1741-2552/ac60c9.
2
Design Analysis and Circuit Topology Optimization for Programmable Magnetic Neurostimulator.
Annu Int Conf IEEE Eng Med Biol Soc. 2021 Nov;2021:6384-6389. doi: 10.1109/EMBC46164.2021.9630915.
3
Multi-locus transcranial magnetic stimulation-theory and implementation.
Brain Stimul. 2018 Jul-Aug;11(4):849-855. doi: 10.1016/j.brs.2018.03.014. Epub 2018 Mar 23.
4
Multi-locus transcranial magnetic stimulation with pulse-width modulation.
Brain Stimul. 2025 May-Jun;18(3):948-956. doi: 10.1016/j.brs.2025.04.014. Epub 2025 Apr 14.
5
A 3-axis coil design for multichannel TMS arrays.
Neuroimage. 2021 Jan 1;224:117355. doi: 10.1016/j.neuroimage.2020.117355. Epub 2020 Sep 9.
6
Electronically switchable sham transcranial magnetic stimulation (TMS) system.
PLoS One. 2008 Apr 9;3(4):e1923. doi: 10.1371/journal.pone.0001923.
7
TMS with fast and accurate electronic control: Measuring the orientation sensitivity of corticomotor pathways.
Brain Stimul. 2022 Mar-Apr;15(2):306-315. doi: 10.1016/j.brs.2022.01.009. Epub 2022 Jan 14.
8
A real electro-magnetic placebo (REMP) device for sham transcranial magnetic stimulation (TMS).
Clin Neurophysiol. 2007 Mar;118(3):709-16. doi: 10.1016/j.clinph.2006.11.005. Epub 2006 Dec 22.
10
Transcranial magnetic stimulation--a sandwich coil design for a better sham.
Clin Neurophysiol. 2006 Feb;117(2):440-6. doi: 10.1016/j.clinph.2005.09.025. Epub 2005 Dec 22.

引用本文的文献

2
xTMS: A Pulse Generator for Exploring Transcranial Magnetic Stimulation Therapies.
Conf Proc (IEEE Appl Power Electron Conf Expo). 2023 May 31;2023:1875-1880. doi: 10.1109/APEC43580.2023.10131554.
3
Optimal Design of Array Coils for Multi-Target Adjustable Electromagnetic Brain Stimulation System.
Bioengineering (Basel). 2023 May 9;10(5):568. doi: 10.3390/bioengineering10050568.
4
A C-shaped miniaturized coil for transcranial magnetic stimulation in rodents.
J Neural Eng. 2023 Mar 24;20(2):026022. doi: 10.1088/1741-2552/acc097.
5
Devices and Technology in Transcranial Magnetic Stimulation: A Systematic Review.
Brain Sci. 2022 Sep 9;12(9):1218. doi: 10.3390/brainsci12091218.
6
Pulse width modulation-based TMS: Primary motor cortex responses compared to conventional monophasic stimuli.
Brain Stimul. 2022 Jul-Aug;15(4):980-983. doi: 10.1016/j.brs.2022.06.013. Epub 2022 Jul 2.

本文引用的文献

1
Neuromodulation in 2035: The Neurology Future Forecasting Series.
Neurology. 2022 Jan 11;98(2):65-72. doi: 10.1212/WNL.0000000000013061.
2
Design Analysis and Circuit Topology Optimization for Programmable Magnetic Neurostimulator.
Annu Int Conf IEEE Eng Med Biol Soc. 2021 Nov;2021:6384-6389. doi: 10.1109/EMBC46164.2021.9630915.
3
Comparison between the modelled response of primary motor cortex neurons to pulse-width modulated and conventional TMS stimuli.
Annu Int Conf IEEE Eng Med Biol Soc. 2021 Nov;2021:6058-6061. doi: 10.1109/EMBC46164.2021.9629605.
5
Systems Neuroengineering: Understanding and Interacting with the Brain.
Engineering (Beijing). 2015 Sep;1(3):292-308. doi: 10.15302/j-eng-2015078. Epub 2016 Mar 16.
6
Estimation of the Motor Threshold for Near-Rectangular Stimuli Using the Hodgkin-Huxley Model.
Comput Intell Neurosci. 2021 May 31;2021:4716161. doi: 10.1155/2021/4716161. eCollection 2021.
7
Paralleling insulated-gate bipolar transistors in the H-bridge structure to reduce current stress.
SN Appl Sci. 2021;3(4):406. doi: 10.1007/s42452-021-04420-y. Epub 2021 Mar 2.
8
Identification of psychiatric disorder subtypes from functional connectivity patterns in resting-state electroencephalography.
Nat Biomed Eng. 2021 Apr;5(4):309-323. doi: 10.1038/s41551-020-00614-8. Epub 2020 Oct 19.
9
Programmable Transcranial Magnetic Stimulation: A Modulation Approach for the Generation of Controllable Magnetic Stimuli.
IEEE Trans Biomed Eng. 2021 Jun;68(6):1847-1858. doi: 10.1109/TBME.2020.3024902. Epub 2021 May 21.
10
A 3-axis coil design for multichannel TMS arrays.
Neuroimage. 2021 Jan 1;224:117355. doi: 10.1016/j.neuroimage.2020.117355. Epub 2020 Sep 9.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验